IP 710 Manual
19
10. Set up IP phone properties in AltiWare as described in step
5 on page 10.
Verifying the Phone Startup Process
After the IP 710 has power connected to it, the phone begins its automatic
booting process by cycling through these steps:
1. All LED lights will be on.
2. The LCD screen displays
[ATGN BOOT]
on the first line.
3. On the second line of the LCD screen, the following messages are
displayed in succession:
—
CHECK MEMORY
(RAM checking state)
—
CHECK FW
(Firmware checking state)
—
INIT NETWORK
—
LOADING FW...
—
LOADING NOW.
—
Boot Done
—
INITIALIZING
Resolving Errors Upon Startup
If an error occurs during booting, the LED light of the following soft keys
will remain on to indicate an error status. These errors represent hardware
failures within the IP Phone.
• Intercom LED light on = memory check failed
• Handset LED light on = network failed
• Conference LED light on = DHCP failed
• Hold LED light on = attached IP address failed
If the phone successfully passes through these stages, it has started up
properly. Otherwise, refer to “Troubleshooting” on page 49.