8 | 16
Notice:
Supply and signal current: In ignition protection type intrinsically safe Ex ib IIB to connect in a
certified safe circuit with the following limits:
Ui
=
28 VDC
Ci
=
negligible
Ii
=
110 mA
Li
=
negligible
Pi
=
770 mW
Thermal:
Environmental temperature range:
-25°C … +60°C
II 2 G Ex ib IIB T4 Gb
4 Terminal Assignment
The electrical connections of the inclination measuring system are made via a cable (e.g. Unitronic-FD CP
plus, 1x2x0,25mm², outer sheath: polyurethane mix), which, depending on version of the system may vary
in length. The maximum of the length is 120 m. The cable shield is connected to the systems case. The
cable has to be laid effectively protected against damages.
Cable Unitronic-FD CP plus, 1x2x0,25 mm²
Clamp
Description
Color
1
+24VDC
white
2
Signal
brown