SM1180 & TM060
The SM1180 has been developed to power and monitor our
remotable microwave head type TM060.
The SM1180 power supply may be used also to power
microwave generators (heads) developed by others manufactu-
rers under condition that they are electrically compatible. See
the electrical specifications of the unit on the next pages.
The reduced height of the rack (only 7HE, corresponding to
310 mm) allows to use small boards, even in big plant: i.e. in a
standard board with an height of 2 meters, arranged to receive
19” racks, up to 5 SM1180 units may be housed.
The user must provide a proper cooling flow: the cooling air
enter into the unit from the front panel, it passes through the
internal circuits and components, then it goes out from the
rear panel.
The intake air flow is approx. 200 m³/h.
The rear panel comprises the following:
- a 7 pins socket for main supply (Conn. #1)
- the fuses holders
- a 14 pins socket for the signals (Conn. #2)
- a 7 pins socket to power the remote microwave head (Conn. #3)
- a 9 pins socket for the signals coming from the remote
microwave head (Conn. #4)
- a 4 pins socket for the high voltage output (Conn. #5)
- a 2 pins terminal to allow remote head “INTERLOCK” func-
tion (Conn. #6);
if you don’t use this feature then let the jumper between the 2 pins
unchanged (= connected)
- a 2 position key switch to enable the panel potentiometer;
pos. 0 = potentiometer disabled; pos. 1 = potentiometer enabled
- a “READY” contact (closed when the unit is ready to gene-
rate anodic current).
- the outlet of the cooling air.
The rear panel of the version 54 and 55 comprises also the
following:
- a 3 pins socket to power the auxiliary section (Conn. #7)
vers. 4/5
vers. 54/55
Содержание SM 1180 Series
Страница 20: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 19 of 35 SM1180 TM060 Components layout...
Страница 25: ...page 24 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060 Pin out of connector 2...
Страница 31: ...page 30 of 35 File SM1180_r9eng December 2007 Technical note SM1180 TM 060 SM1180 TM060...
Страница 32: ...File SM1180_r9eng December 2007 Technical note SM 1180 TM 060 page 31 of 35 SM1180 TM060 Wiring example...