ALTER FX 950 T Скачать руководство пользователя страница 3

    

FX 950 T 

page    2  

of 8

                                                                                                                                           File: FX950T_r0eng -  April 2004   -    Technical note: FX 950 T

 File: FX950T_r0eng -  April 2004   -    Technical note: FX 950 T                                                                                                                                

          

page     3  

of  8

    

FX 950 T 

General Description

FX950T is a stabilized ferro-resonant power supply unit, 

with a fixed output, for a 3kW powered magnetron.

The power supply unit must be connected to the

2 x 400V/50Hz electric network without neutral, and is 

provided in “open frame ” version to be assembled in the 

electrical panel.

General Information

The FX 950 T power supply unit is in compliance 

with the EN 61010-1 (=CEI 66-5) European Standard 

approved by Cenelec on 9/3/1993. As provided by 

this standard, the equipment must be installed and 

used exclusively by qualified personnel instructed on 

the precautions and operating mode. The generator, if 

correctly installed, is in compliance with the expected 

radio noise limits for Group 2, Class A equipment 

provided by the EN 55011 regulation.

CAUTION!

FX 950 T is powered through the mains: read this 

manual carefully before installing the equipment. 

Make sure that the electric connection and the 

utilisation are correct.

Failure to comply with the instructions implies serious 

risks for the personnel in charge of the equipment 

utilisation, as well as the possibility to cause 

equipment breakdowns.

Electric Specifications

Power supply (rated): 

 

 

400Vac, 50Hz

Minimum input voltage:   

 

360V

Maximum input voltage:   

 

440V

Input current (average value):   

11 A @ 400V  

Rating: 

 

 

4400 VA

Efficiency: 

 

 

95%

Magnetron power: 

 

 

3 kW

Outgoing stability: 

 

 

+/-7%

Outgoing anodic current:   

 

840 mA

Magnetron: 

 

 

2M265-M12

Environmental working conditions

Operating mode:  

only inside the panel

Altitude: 

 

tested up to 2,000 m above sea    

 

 

 

level

Temperature:   

from 5 °C to 40 °C

Relative humidity: 

80% up to 31 °C, linear decrease  

 

 

 

by 50% at 40 °C

Level of pollution: 

2, in compliance with IEC664 

Fuse specifications

FX 950 T has two (F1 and F2) fuses assembled on 

the control card and one (F3) fuse assembled on the 

autotransformer.

F1 fuse data:

- Size, type

 

 

5 x 20 mm

- Operating speed

 

delayed (T)

- Rated current

 

2 A

- Rated voltage

 

250 V

F2 fuse data:

- Size, type

 

 

5 x 20 mm

- Operating speed

 

delayed (T)

- Rated current

 

100 mA

- Rated voltage

 

250 V

F3 fuse data:

- Size, type

 

 

5 x 20 mm

- Operating speed

 

delayed (T)

- Rated current

 

1 A

- Rated voltage

 

250 V

Содержание FX 950 T

Страница 1: ...FX 950 T POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE Issue April 2004 ...

Страница 2: ...che il Prodotto product name FX950 nome del prodotto FX950 model FX950T modello FX950T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011 1991 The products listed above comply with the requirements of the Low Voltage Directive 73 23 EEC I Prodotti sopraindicati sono conformi con la Direttiva di Bassa Tensione 73 23 EEC Reggio Emilia A...

Страница 3: ...nnection and the utilisation are correct Failure to comply with the instructions implies serious risks for the personnel in charge of the equipment utilisation as well as the possibility to cause equipment breakdowns Electric Specifications Power supply rated 400Vac 50Hz Minimum input voltage 360V Maximum input voltage 440V Input current average value 11 A 400V Rating 4400 VA Efficiency 95 Magnetr...

Страница 4: ... V transformer 42AN4500 3 1 5x20 2A T 250V fuse F1 4 2 H V Diode 80D815 5 1 Measure resistance RSZ25002R 6 1 400V 230V autotransformer 42ATC140 001 7 1 5x20 100 mA T 250V fuse F2 8 1 5x20 1A T 250V fuse F3 9 1 Control card 800000330 10 1 Data label List of components 1 2 3 4 5 6 7 Co nnection of the high voltage cable to the magnetron 400 V input Earth screw 8 9 10 ...

Страница 5: ...ch must comply with the EN 61010 1 standard it must be installed near the power supply unit and easily reachable by the user VII In order to carry out the connection to the terminal board of J2 mains input make sure that the mains is not connected through a the external switch Failure to comply with these instructions is dangerous for those who use the equipment apart from the possibility to cause...

Страница 6: ... case of current leakage due to humidity or dirt along the high voltage path After activating ENABLING if no interlocked conditions are present the ABIL MW led is lit on M330 Within 5 seconds the filament voltage limitation relay is switched the RIDUZ FILAM led is fully lit and the filament voltage drops to an appropriate value NOTES 1 When ENABLING is activated no power is supplied if any of the ...

Страница 7: ...pril 2004 Technical note FX 950 T Wiring diagram of FX950T power supply unit with TX030 head Caution it is compulsory to connect the earth screw of the head to the earth screw of the power supply unit failure to do this may cause a death risk ...

Страница 8: ...File FX950T_r0eng April 2004 Technical note FX 950 T page 7 of 8 FX 950 T EXTERNAL WIRING DIAGRAM ...

Страница 9: ...m How to order Power supply unit for filament FX 950 T Alter reserves the right to make improvements or changes to the product described in the manual at any moment and without prior notice This publication cannot be reproduced without the written consent of Alter All rights are reserved View of the power supply unit Physical characteristics width 250 mm height 235 mm depth 676 mm weight 40 kg ...