General Description
FX950T is a stabilized ferro-resonant power supply unit,
with a fixed output, for a 3kW powered magnetron.
The power supply unit must be connected to the
2 x 400V/50Hz electric network without neutral, and is
provided in “open frame ” version to be assembled in the
electrical panel.
General Information
The FX 950 T power supply unit is in compliance
with the EN 61010-1 (=CEI 66-5) European Standard
approved by Cenelec on 9/3/1993. As provided by
this standard, the equipment must be installed and
used exclusively by qualified personnel instructed on
the precautions and operating mode. The generator, if
correctly installed, is in compliance with the expected
radio noise limits for Group 2, Class A equipment
provided by the EN 55011 regulation.
CAUTION!
FX 950 T is powered through the mains: read this
manual carefully before installing the equipment.
Make sure that the electric connection and the
utilisation are correct.
Failure to comply with the instructions implies serious
risks for the personnel in charge of the equipment
utilisation, as well as the possibility to cause
equipment breakdowns.
Electric Specifications
Power supply (rated):
400Vac, 50Hz
Minimum input voltage:
360V
Maximum input voltage:
440V
Input current (average value):
11 A @ 400V
Rating:
4400 VA
Efficiency:
95%
Magnetron power:
3 kW
Outgoing stability:
+/-7%
Outgoing anodic current:
840 mA
Magnetron:
2M265-M12
Environmental working conditions
Operating mode:
only inside the panel
Altitude:
tested up to 2,000 m above sea
level
Temperature:
from 5 °C to 40 °C
Relative humidity:
80% up to 31 °C, linear decrease
by 50% at 40 °C
Level of pollution:
2, in compliance with IEC664
Fuse specifications
FX 950 T has two (F1 and F2) fuses assembled on
the control card and one (F3) fuse assembled on the
autotransformer.
F1 fuse data:
- Size, type
:
5 x 20 mm
- Operating speed
:
delayed (T)
- Rated current
:
2 A
- Rated voltage
:
250 V
F2 fuse data:
- Size, type
:
5 x 20 mm
- Operating speed
:
delayed (T)
- Rated current
:
100 mA
- Rated voltage
:
250 V
F3 fuse data:
- Size, type
:
5 x 20 mm
- Operating speed
:
delayed (T)
- Rated current
:
1 A
- Rated voltage
:
250 V