ALTER FX 950 T Скачать руководство пользователя страница 1

FX 950 T

 

 

 

 

 

 

 

 

 

    POWER SUPPLY UNIT 

FOR 3 KW MAGNETRON

TECHNICAL NOTE

(Issue April 2004)

Содержание FX 950 T

Страница 1: ...FX 950 T POWER SUPPLY UNIT FOR 3 KW MAGNETRON TECHNICAL NOTE Issue April 2004 ...

Страница 2: ...che il Prodotto product name FX950 nome del prodotto FX950 model FX950T modello FX950T Complies with the following norms Soddisfa le seguenti norme EN 61010 1 1994 A2 1996 EN 61010 1993 A2 1995 EN55011 1991 The products listed above comply with the requirements of the Low Voltage Directive 73 23 EEC I Prodotti sopraindicati sono conformi con la Direttiva di Bassa Tensione 73 23 EEC Reggio Emilia A...

Страница 3: ...nnection and the utilisation are correct Failure to comply with the instructions implies serious risks for the personnel in charge of the equipment utilisation as well as the possibility to cause equipment breakdowns Electric Specifications Power supply rated 400Vac 50Hz Minimum input voltage 360V Maximum input voltage 440V Input current average value 11 A 400V Rating 4400 VA Efficiency 95 Magnetr...

Страница 4: ... V transformer 42AN4500 3 1 5x20 2A T 250V fuse F1 4 2 H V Diode 80D815 5 1 Measure resistance RSZ25002R 6 1 400V 230V autotransformer 42ATC140 001 7 1 5x20 100 mA T 250V fuse F2 8 1 5x20 1A T 250V fuse F3 9 1 Control card 800000330 10 1 Data label List of components 1 2 3 4 5 6 7 Co nnection of the high voltage cable to the magnetron 400 V input Earth screw 8 9 10 ...

Страница 5: ...ch must comply with the EN 61010 1 standard it must be installed near the power supply unit and easily reachable by the user VII In order to carry out the connection to the terminal board of J2 mains input make sure that the mains is not connected through a the external switch Failure to comply with these instructions is dangerous for those who use the equipment apart from the possibility to cause...

Страница 6: ... case of current leakage due to humidity or dirt along the high voltage path After activating ENABLING if no interlocked conditions are present the ABIL MW led is lit on M330 Within 5 seconds the filament voltage limitation relay is switched the RIDUZ FILAM led is fully lit and the filament voltage drops to an appropriate value NOTES 1 When ENABLING is activated no power is supplied if any of the ...

Страница 7: ...pril 2004 Technical note FX 950 T Wiring diagram of FX950T power supply unit with TX030 head Caution it is compulsory to connect the earth screw of the head to the earth screw of the power supply unit failure to do this may cause a death risk ...

Страница 8: ...File FX950T_r0eng April 2004 Technical note FX 950 T page 7 of 8 FX 950 T EXTERNAL WIRING DIAGRAM ...

Страница 9: ...m How to order Power supply unit for filament FX 950 T Alter reserves the right to make improvements or changes to the product described in the manual at any moment and without prior notice This publication cannot be reproduced without the written consent of Alter All rights are reserved View of the power supply unit Physical characteristics width 250 mm height 235 mm depth 676 mm weight 40 kg ...

Отзывы: