background image

N O T D E M 0 U K 0 0 0 0 3 9 - V 1 . 0 1

QUICK START GUIDE

 

Range of wireless sirens 869 MHz 
 

Made in FRANCE

 

SIRENS RF 

This quick start guide allows quickly installing the PILOTE RF and its sirens in the factory settings.  
For any other operation, please see the complete technical manual.  

 

1- INSTALLATION 

 

REQUESTED MOUNTING DIRECTION 

SIRYNX RF 

SIRUS RF 

PILOTE RF 

 
 
 
 
 
 
 
 

 

 

 

2-  CONNECTION OF THE SIRENS BATTERIES 

 

Connect imperatively two batteries to the electronic card to ensure the autonomy of the 
SIRYNX RF and of the SIRUS RF. 

 
 
 
 
 
 
 
 
 

 

 
 

3-  DESCRIPTION OF THE CONNECTION TERMINAL OF THE PILOTE RF 

 
 

0V 

DC 

Charge 

+12V 

The power 12V continues to be supplied by an uninterruptible power supply 
with limited power. 

Output for supervision failure  (by default = 0V) 

Output for the failure of sirens low battery  (by default = 0V) 

OUTPUTS 

Output for the failure of the PILOTE RF batteries   (default = 0V) 

  CMD 

Input of command configurable  

Factory settings :   Information Arm/Disarm 

                                Alarm by disappear of 12V 

INPUTS 

BL.SIR 

Input of sirens blocking configurable 

Factory settings :   Triggering of all the sirens 

                                 Alarm by disappear of 12V

 

A.P.      TAMPER 

Tamper protection 

TOP 

  TOP 

TOP 

CAUTION 
MANDATORY 

Get the wires to 
the bottom of 
the housing  

 

SIRYNX RF 
BATTERIES 
CONNECTORS

SIRUS RF 
BATTERIES  
CONNECTORS