background image

ALTEC

Power
220V AC

ALTEC

深圳市亚特克电子有限公司

Shenzhen

 

ALTEC

 

Electronics

 

Co.,

 

LTD.

- 2 3

RL1

°

(

P

S

MTC35

A

L

T

E

C

5

4

1

2

6

7

8

OUT2

OUT1

1 2 3 4 5 6 7 8 9 10 11 12

NTC
Temp. sensor

MTC35-C30-2T-2R-220V

MTC35-C30
Environmental Temperature Controller

Instruction Manual

2. Coding

 

① 

Software Function

C30

Environmental Temp. controller

② 

Input

③ 

Output

2T

2 temperature sensors

2R

2 Relays

MTC35-C30-2T-2R-220V

① ② ③

 

Power Supply

220V

220V AC

1. Introduction

 

The  MTC35-C30  Temperature  Controller  is  a  particularly  flexible  controller,  which 

allows On/Off control of room temperature for energy saving.

The  controller  has  two  temperature  sensors(one  for  indoor,  other  for  outdoor)  as 

input  and  two  outputs  which  are  controlled  by  a  MCU  according  to  value 

programmed for the parameters in Parameter List.

Temperature sensor: NTC, range: -50~150 °C.

To  get  the  best  performance,  before  installing  and  using  it,  read  this  instruction 

manual carefully.

1)

 

Prepare a rectangular cut-out in the mounting panel to the size

 

.

2)

 

Insert the controller from the front panel cut-out

.

3)

 

From behind of the panel, slide the mounting brackets into the guides on the side 

of the housing. The flat faces of the mounting brackets must lie against the housing.

4)

 

Push the mounting brackets up to the back of the panel, and tighten them evenly.

72

×

30mm

Note:

Please

 

completes waterproof processing

 

properly

,

 in

 

order to avoid seeps causes 

the instrument damage

.

3. Dimensions and Mounting

 

3

5

2

8

78

72

6

888

P

S

①.

Up Key

②.

Down Key

③.

Dispaly

     Indicates PV,

     Parameters and Values

④.

Setting Key(S)

⑤.

Parameter Key(P)

4. Front Panel Layout

3

⑥.

Output 1 indicator(RL1)

⑦.

Output 2 indicator(RL2)

⑧.

PV2 displaying indicator(PV2)

     lit when outdoor temperature is   

     displaying

5. Electrical Connection

 

6.1 Viewing the PV

Mounting  and  wire  up  the  controller  and  switch  on,  3  seconds  later,  the  indoor 

measured  temperature  will  appear  on  display.  Indoor  temperature  T1  and  outdoor 

temperature T2 displaying can be exchange by pressing S key. When the ‘Outdoor 

Temp. displaying indicator’ is lit, the display indicates the outdoor temperature.

6.2 Setpoint Adjusting

During  the  basic  functioning,  press  key  'P'  and  hold  for  1  second,  temperature 

setpoint 

K,L

  appears  on  the  display.  Press  key  'S',  the  value  of 

K,L

  appears;  press 

keys 

  or 

  to  increase  or  decrease  setpoint.  Keeping  it  pressed  results  in  a 

progressively  faster  variation.  Press    key  'P'  again,  next  parameter 

LOL

  appears, 

setting its value in the same way.

6. Operation

 

WWW.ALTEC.CC

Indoor

T1

Outdoor

T2

N

L

F

C

C: Air Conditioner
F: Aeration Fan

Отзывы: