INSTALLATION AND WIRING 

Although the SLC308-8T can be mounted into a sheetrock or 
plaster ceiling, the following installation procedure is intended 
for suspended tile ceilings. Note: We recommend that you order 
the mounting ring (SLC-RING), not included, when installing the 

SLC308-8T into a sheetrock or plaster ceiling. 
 
1.

 

Place ceiling tile, finished side facing up, over the flat, 12 in. 
(305 mm) to 22 in. (559 mm) diameter opening of a container 
such as a Rubbermaid

®

 32 gallon Brute

®

 model 2632. 

2.

 

Locate the approximate center of the mounting hole that is to 

be  cut,  and  mark  this  spot  on the ceiling tile. Note: This 
center can be located anywhere along the length of the 
ceiling tile that is at least 8 in. (203 mm) from either end and 
equidistant from each side edge. 

3.

 

Align the center of the 10.75 in. (273 mm) tile bridge hole 

with the spot marked as the center, and position the metal 
tile bridge flat against the ceiling tile with the ends of the tile 
bridge aligned to the side edges of the ceiling tile. 

4.

 

Carefully, so as not to damage the ceiling tile, temporarily 
secure the tile bridge in-place with adjustable torsion clamps 
such as C-clamps. 

5.

 

Guide the blade of a RotoZip

®

 RZ01, or similar rotary cutting 

tool, against the edge of and completely around the 10.75 in. 
(273 mm) tile bridge hole, cutting the ceiling tile hole. 

6.

 

Remove the torsion clamps and tile bridge from the ceiling 
tile. 

7.

 

Install the ceiling tile in the ceiling’s T-grid. 

8.

 

Install the tile bridge on top of the ceiling tile, and align the 
tile bridge hole with the newly cut ceiling tile hole. 

9.

 

Pull the wiring and or flex conduit through the tile bridge and 
ceiling tile holes. 

10.

 

Attach one end of the S-hook to the SLC308-8T’s metal strain 

relief strap and rest the other end of the S-hook, through the 
mounting hole, on the top surface of the tile bridge. 

11.

 

Connect the audio transmission (-) wire (usually black) to the 
black wire of the SLC308-8T, and connect the audio 
transmission (+) wire to the red wire of the SLC308-8T. Secure 

a sufficient insulator cover over these connections. Note: 
Proper rated wire-nuts are recommended to insulate these 
connection points. 

12.

 

If flex conduit is used, pack the excess wire into the conduit 
(including the wire nuts), and secure the flex conduit with the 
½ in. (13 mm) connector. 

13.

 

Remove the S-hook and gently push the SLC308-8T (and 
excess conduit or wire) up into the hole and tighten the three 
mounting screws, causing the dogleg arms to swing out and 
anchor the enclosure to the metal tile bridge. 

14.

 

Snap on the metal grille. 

 

ARCHITECT’S AND ENGINEER’S SPECIFICATIONS 

The loudspeaker system shall be an in-ceiling design, consisting 
of a Duplex

®

 8 in. (203 mm) diameter cone woofer and a 3 in. (76 

mm) diameter cone tweeter. This loudspeaker component shall 
have a power rating of 16W AES (64W peak). The loudspeaker 
system shall have an operating bandwidth of 130 Hz to 20 kHz,

 

with a sensitivity of 97 dB at one watt, when measured at one 
meter. The loudspeaker system shall include a 5-position switch 
for adjustable load/output requirements. The switch shall 
terminate the two 18 gauge input wires directly to the nominal 8 
ohm impedance of loudspeaker component, or indirectly to the 

loudspeaker component through a step-down, multi-tap 8W 
transformer. This transformer shall have an insertion loss of < 0.6 
dB. The loudspeaker component, switch and transformer shall be 
assembled into a moisture resistant black-painted steel enclosure 
with internal damping material. The enclosure diameter shall be 
9.31 in. (236 mm), the enclosure’s baffle diameter shall be 11.75 

in. (298 mm), and the enclosure’s depth shall be 7.85 in. (199 
mm), including the ½ in. (13 mm) flex-conduit connector. The 
loudspeaker system shall include a 12.75 in. (324 mm) diameter, 
one-piece, snap-on, off-white-painted steel grille; and a 23.75 in. 
(603 mm) long, 14 in. (356 mm) wide, 20 gauge galvanized steel 

tile bridge. The loudspeaker system shall be the Altec Lansing 
Professional model SLC308-8T. 
 
 
 
 

 
 
 
 

 

 

SPECIFICATION NOTES 

1

  The frequency response of the loudspeaker system is measured at a distance of no less than 3 meters to obtain full range data. The 

level is then corrected to be equivalent to a 2.83 V 1 m measurement. A near field measurement of the system is performed for 

frequencies below 500 Hz. This data is then combined with the full range measurement to give an accurate composite frequency 
response curve. 

2

 The limits of the frequency response are referenced to -5 dB of the loudspeaker’s rated sensitivity in the SLC’s 0.25 ft.

3

 sealed 

enclosure. 

3

  The sensitivity of the loudspeaker system is the log based average SPL taken over the intended bandwidth of operation for the system 

with a 2.83 V swept sine stimulus. The data is measured and level corrected in a manner consistent with note 1. 

4

  The power handling capacity of the loudspeaker system is tested using a full range form of AES Standard 2-1984. The test stimulus is 

band limited (40 Hz – 16 kHz) pink noise with a 6 dB crest factor. The applied RMS voltage is determined using the minimum impedance 
of the system. The amplifier used to drive the loudspeaker has a minimum operating headroom of 6 dB referenced to the RMS voltage. 

5

  The peak output level of the system is calculated based on the sensitivity and the peak power handling capabilities of the system. 

6

  The coverage angles for the loudspeaker are taken as the -6 dB points of the directivity response and averaged from 500 Hz to 16 kHz. 

7

  The minimum impedance of the loudspeaker is taken over its intended band of operation. 

As we are continually striving to improve Altec Lansing products, specifications are subject to change without notice. 

 

VISIT 

WWW.ALTECPRO.COM

 FOR

 

 

Authorized EASE data on all Altec Lansing Professional loudspeakers 

 

PDF specification sheets. Download page 1 of the specification sheet for you submittals. 

 

One paragraph A&E Specifications in .doc format 

 

The latest information on Altec Lansing Professional products. 

 

Performance specifications for the CD308-series speakers, including the one-octave polar response charts. 

 

© 2004 Altec Lansing Professional 

y

 1000 W. Wilshire Blvd., Suite 362 

y

 Oklahoma City, Oklahoma 73116 

Phone: 1.405.848.3108 

y

 Fax: 1.405.848.3217 

y

 Email: 

[email protected]

 

Revision 01 

20

50

100

200

500

1 k

2 k

5 k

10 k

20 k

Frequency (Hz)

60

70

80

90

100

110

dB

SPL

(ref:

20

Pa)

Frequency Response