POWER CONNECTIONS

 

The power transformer of the 1570B Amplifier has primary taps for 117 and 128 volts and is shipped with the 128 volt 
tap (white lead) connected. Use of the 128 volt tap for all line conditions will extend component and tube life, reducing 
maintenance to a minimum. Do not connect the 117 volt tap unless 24-hour line checks show that the line does not exceed 
117 volts. For your convenience, these two leads are equipped with ring type terminals, the one in use being connected to 
one terminal of the interlock microswitch and the unused terminal insulated with plastic tubing.

 

POWER OUTPUT

 

When making power output measurements, connect a jumper across the terminals of the 
thermal breaker. Continuous sine wave output in the full power range may operate the 
breaker, giving false readings, if the jumper is not used. In motor drive or other applica-
tions which require continuous sine wave full power output of the 1570B, the thermal 
breaker should likewise be bridged out of the circuit.

 

CONTROLS

 

Two controls are provided: Volume control and AC power switch. Provision has been 
made for mounting an accessory relay to provide plate power keying by remote control. 
The mounting holes are located near the center of the chassis and are suitable for a Potter-
Brumfield type PR-3 relay or equivalent which should be mounted under the chassis. 
Select a relay having the desired coil voltage. If control wiring and microphone lines are 
carried in the same conduit, use a DC type relay. The white wire from the cable form to 
terminal 6 on V-9 tube socket should be transferred from this terminal to one contact on 
the relay. Connect the other relay contact to terminal 6, V-9 socket.

 

SERVICING

 

When the top cover is removed for tube replacement, etc., an interlock switch interrupts the AC line voltage to the power 
transformer. Do not attempt service work on this amplifier with AC line voltage on, as approximately 1,000 volt potentials 
occur at various points. Discharge all filter condensers before making continuity or resistance measurements. Routine ser-
vicing may then be done using the schematic for pertinent data reference. If high voltage measurements must be made, 
proceed with caution.

 

 

PARTS LIST

 

C1 

.0002 mfd. ±10%, 600v ceramic, Erie GP2-331 

R18 

75,000 ohms, 20 watt, Ohmite Brown Devil

 

C2, 3 

.22 mfd., 400v, Astron BP4-22 

R19 

5 ohms, 50 watt, Ohmite 0400A

 

C4, 5 

.1 mfd., 600v, CD PM6 P 1 

R20 

10 ohms ±10%, 1/2

 

watt

 

C6 

40x40 mfd., 500v, Mallory FP288 

P1 

Altec Lansing 12435

 

C7, 11 

120 mfd., 200v, Mallory FP121 

BR1 

Klixon CA3 Thermal Breaker

 

C8 

6 mfd., 1000v, Tobe-Deutchmann TAB-1006 

PL1 

G .E .  M a zd a   # 4 4

 

C9 

,0056 mfd. ±10%, 600 v ceramic, Erie 811 

T1 

Peerless 16492

 

C10 

.0022 mfd. ±10%, 600v ceramic, Erie GP-2 

T2 

Peerless 6410

 

R1 

1000 ohms ±10%, 1/2

 

watt 

L1 

Peerless 17173

 

R2 

330,000 ohms ± 5%,  1 watt 

L2 

Peerless 17266

 

R3, 21 

100,000 ohms ±10%, 1/2

 

watt 

S1 

Altec Lansing 12763

 

R4, 5, 9, 10, 17     100,000 ohms ±10%, 1 watt 

S2 

Interlock, V3-1 Microswitch

 

R6, 7 

2.2 megohms ±10%, 1/2

 

watt 

RS1, 2 

G.E. 1N1695 Silicon Rectifier

 

R8 

1800 ohms ±10%, 1/2

 

watt 

V1 

12AX7 Vacuum Tube

 

R11, 12 

330,000 ohms ± 10%, 1/2

 

watt 

V2 

6SN7GTB Vacuum Tube

 

R13 

82,000 ohms ±10%, 1/2

 

watt 

V3, 4 

6W6GT Vacuum Tube

 

R14 

600 ohms, 5 watt, Ward Leonard Type 5 

V5, 6 

811-A Vacuum Tube

 

R15, 16 

100 ohms ±10%, 1/2

 

watt 

V7, 8, 9, 10 

5R4GY Vacuum Tube

 