8.14 Setting the System Pressure
8.14.1
Remove the Front Panel (section 8.10 ).
With Compressor running:
8.14.2
Pull the Capacity Control
Valve knob out.
8.14.3
Turn the knob until the
reading on the Pressure
Gauge is
50 PSI
.
8.14.4
Push the knob in to lock.
8.14.5
Reinstall the Front Panel (section 8.10 ).