background image

Altec AIR CO2-PG14 CO2-Free Gas Generator Operations and Maintenance Manual

 

 

Page 9

 

 

P012548-14 - Rev D 

 

 
 
 
 

 

 
 

 

Tel:  800-521-5351 

226A Commerce St., Broomfield, CO. 80020 

[email protected] 

 

 

 
 
SECTION 9  WIRING 

 

 

CO2-PG14 WIRING DIAGRAM 

 

SECTION 10  WARRANTY 
 

Altec  AIR  warrants  the  CO2-PG14  to  be  free  of  defects  in 
materials  and  workmanship  under  proper  use,  installation  and 
application.    This  limited  warranty  shall  cover  parts  or 
replacement  unit  only,  for  a  period  of  18  months  from  date  of 
shipment  or  12  months  from  date  of  installation,  whichever 
comes first. 
 
ALL 

FREIGHT 

DAMAGE 

CLAIMS 

ARE 

NOT 

THE 

RESPONSIBILITY OF THE MANUFACTURER AND ARE NOT 
COVERED  UNDER  WARRANTY  AS  ALL  PRODUCTS  ARE 
SHIPPED F.O.B. SHIPPER.  PLEASE DIRECT ALL FREIGHT 
CLAIMS TO THE FREIGHT CARRIER IN QUESTION. 
 
This warranty does not apply to any unit damaged by accident, 
modification, misuse, negligence, or misapplication.  
 
Any covered CO2-PG14 part or material found defective will be 
repaired,  replaced  or  refunded,  at  Altec  AIR’s  option,  free  of 
charge,  provided  that  Altec  AIR  is  notified  within  the  above 
stated warranty period.  All returns of defective parts/equipment 
must have prior written Returned Material Authorization (RMA).  
RMA  may  be  obtained  from  our  service  department.    All 
defective  parts/equipment  must  be  returned  freight  prepaid  to 
the  Altec  AIR  factory  within  30  days  of  RMA  issue  date.    Any 
shipment returned to the factory collect will be refused. 
 
If  an  item  is  found  to  be  warrantable,  the  repaired  item  or 
replacement  will  be  shipped  via  standard  ground  freight 
prepaid within the continental US and Canada. 
 
Any replacement part or material is warranted only to the extent 
of the remaining warranty period of the adsorber/dryer or to the 
extent as provided by the supplier, whichever is longer. 

 
All freight damage claims should be filed within 15 working 
days and should be directed to the freight carrier.

 

AC POWER
CORD

AC SOLENOID VALVE

ON-OFF
SWITCH

AC
POWER
IN

L1
L2

GND

DC TIMER

DC

+ –

LOAD
2

1

DC POWER ENTRY
RECEPTACLE
CENTER (+) POSITIVE

DC SOLENOID VALVE

ON-OFF
SWITCH

AC TIMER

AC UNITS

DC UNITS

Содержание CO2-PG14

Страница 1: ...allation Safety Operation Safety SECTION 3 Specifications Pg 3 Flows Connections Dimensions and Weights SECTION 4 Installation Pg 4 Parts Included Location Electrical Connections Piping and Connection...

Страница 2: ...this tower removes CO2 to less than 1 ppm and 99 9 of the water vapor from the air when operated at standard catalog conditions The dry CO2 free air leaving the top of the tower T1 is directed to the...

Страница 3: ...de pressurize the unit before starting installation or maintenance procedures The CO2 PG14 is rated NEMA 1 2 2 OPERATION SAFETY DO NOT OPERATE THE PURGE GAS GENERATOR AT COMPRESSED AIR PRESSURES ABOVE...

Страница 4: ...T IN AN ENVIRONMENT OF CORROSIVE CHEMICALS EXPLOSIVE GASES OR AREAS OF HIGH AMBIENT TEMPERATURE CONDITIONS 4 3 ELECTRICAL CONNECTIONS Before plugging in unit check the unit nameplate for electrical ch...

Страница 5: ...ER DRYER IS DEPRESSURIZED BEFORE WORKING ON THE ADSORBER DRYER OR RELATED EQUIPMENT ENSURE THAT ALL PERSONNEL HAVE READ AND UNDERSTAND THE SAFETY AND OPERATION INSTRUCTIONS IN THIS MANUAL 6 1 PREVENTI...

Страница 6: ...ee Sec 6 1 OUTLET FILTER REGULATOR WITH GAUGE 1 1 1 1 See Sec 6 1 OUTLET FILTER ELEMENT ONLY 1 1 1 1 See Sec 6 1 REGULATOR ONLY 1 1 1 1 50027 TIMER CYCLE 115 VAC 1 50029 TIMER CYCLE 220 VAC 1 51408 TI...

Страница 7: ...ed outlet flow Reduce air usage downstream A4 Dirty or obstructed inlet air filter Check inlet coalescing filter element Replace inlet filter element A5 Purge orifice plugged Check purge air flow with...

Страница 8: ...t air passages and piping for blockages Clear restrictions C PROBLEM EXCESSIVE PURGE POSSIBLE CAUSE CHECK CORRECTIVE ACTION C1 Inlet valve or outlet shuttle not shifting Check for damage or contaminat...

Страница 9: ...be repaired replaced or refunded at Altec AIR s option free of charge provided that Altec AIR is notified within the above stated warranty period All returns of defective parts equipment must have pr...

Отзывы: