background image

 

 
 

Altai Technologies Ltd. All rights reserved 

 

 
 
 

 

Installation Guide 

Version 1.2

 

 

Altai A8n (ac) Series Super WiFi 

Base Station

 

 
 

 

 

Содержание A8-Ein (ac)

Страница 1: ...Altai Technologies Ltd All rights reserved Installation Guide Version 1 2 Altai A8n ac Series Super WiFi Base Station...

Страница 2: ...2015 Altai Technologies Limited ALL RIGHTS RESERVED Altai Technologies Limited Unit 209 2 F Lakeside 2 10 Science Park West Avenue Hong Kong Science Park Shatin New Territories Hong Kong Telephone 852...

Страница 3: ...not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful int...

Страница 4: ...arest ground rod or item that is grounded A8n ac product series require professional installation The installer shall be responsible for ensuring that the proper 5GHz antenna is employed so that the l...

Страница 5: ...AND A8IN AC BASE STATION MOUNTING 8 A8N AC AND A8IN AC BASE STATION MOUNTING KIT 9 MOUNTING A8N AC AND A8IN AC ON POLE 10 MOUNTING A8N AC 2 4GHZ ANTENNA AND CABLE CONNECTION 11 MOUNTING OF A8N AC 2 4G...

Страница 6: ...lt angles ii A8 Ein ac integrated base station multi beam 2 4GHz 19dBi antenna array for 80 degree sector coverage iii A8in ac integrated base station 14dBi antennas and RF cabling optimized for long...

Страница 7: ...iFi Base Station Installation Guide Altai Technologies Ltd All rights reserved A8 Ein ac Base Station Mounting and Outlook Figure 1 back view of A8 Ein ac Grounding Screw Locking screw hole Mounting s...

Страница 8: ...s Hold the reset button until you see Power LED blink once o Then release it immediately Reset to factory default equivalent to UI Reset factory NOT retain network address o Press Hold the reset butto...

Страница 9: ...4 Altai A8n ac Series Super WiFi Base Station Installation Guide Altai Technologies Ltd All rights reserved The reset button s location is shown in following...

Страница 10: ...on Installation Guide Altai Technologies Ltd All rights reserved A8 Ein ac Base Station Mounting Kit A Main mounting module B Mounting back plate C 4x mounting screw and nut D 4x locking screw Figure...

Страница 11: ...must be installed with the key hole pointing down Figure 6 4 Clamp the A8 Ein ac unit to the mounting kit as shown in Figure 7 and make sure the mounting screw is locked in the key hole 5 Screw in 4 l...

Страница 12: ...A8n ac Series Super WiFi Base Station Installation Guide Altai Technologies Ltd All rights reserved Figure 7 Clamping A8 Ein ac unit Figure 8 Secure the unit Figure 9 Antenna Mounted on Pole Tilting...

Страница 13: ...ogies Ltd All rights reserved A8n ac and A8in ac Base Station Mounting Mounting for A8n ac and A8in ac are the same Figure 10 shows the back view of A8in ac A8n ac has the same mounting screw Figure 1...

Страница 14: ...n Guide Altai Technologies Ltd All rights reserved A8n ac and A8in ac Base Station Mounting Kit A Mounting back plate B Main mounting module C 4x mounting screws and nuts D 4x locking screws and nuts...

Страница 15: ...sition Figure 13 3 The mounting kit must be installed with the key hole pointing direction Figure 14 4 Clamp the unit to the mounting kit as shown in Figure 15 and make sure the mounting screw is lock...

Страница 16: ...2 4GHz panel antenna gives you more freedom to adjust the direction and tilting of each antenna Internal 2 4GHz antenna is easier for installation 2 At the top of A8n ac there are 8 N female RF connec...

Страница 17: ...t the 2 4GHz radio antenna to the pole It is recommended that to install the standard A8n ac 2 4GHz antenna with the RF ports facing downward as shown in Figure 17 2 Adjust the direction and down tilt...

Страница 18: ...nd 2 of A8n ac must connect to the same panel antenna The same for ports 3 4 5 6 and 7 8 which each pairs must connect to the same panel antenna It is recommended to connect the A8n ac port to antenna...

Страница 19: ...c Series Super WiFi Base Station Installation Guide Altai Technologies Ltd All rights reserved Figure 20 Antenna port to A8n ac port mapping Figure21 A8n ac 2 4GHz RF port groups Sector 4 Sector 2 Sec...

Страница 20: ...rts 2 Connect RF cables from the A8n ac series 5GHz antenna RF ports which marked a0 and a1 next to the RF ports 3 It is recommended to seal the A8n ac series 5GHz antenna RF ports with weatherproof m...

Страница 21: ...n and strong winds We recommend the following sealing materials for weatherproofing the antenna connectors 1 High quality all weather black plastic electrical tape preferably 3 4 19mm wide to make it...

Страница 22: ...proper adhesion 4 Do not pull the tape to tear it always cut the tape A pulled tape will most likely unravel decreasing protection 5 In warm climates where there will be long exposure to sunlight it...

Страница 23: ...tyl rubber tape around the base of each antenna port in the clockwise direction Take extra care to make sure that the resulting butyl rubber ring would not hinder the tightening of the RF cable connec...

Страница 24: ...available first tighten the connector to finger tight then tighten it with a wrench for an additional to turn from the finger tight position 5 Weatherproof the A8n ac series antenna ports Weatherproof...

Страница 25: ...r of electrical tape from the base of the A8n ac 2 4GHz antenna port Overlap the tape to half width Finish the wrap at 1 25mm above the butyl rubber tape and cut the tape Weatherproofing A8n ac series...

Страница 26: ...e are no gaps Press the tape against the RF cable connector body and the A8n ac series 5GHz antenna RF port 3 Start wrapping a layer of electrical tape 1 25mm below the butyl rubber tape overlapping a...

Страница 27: ...bove any obstacle in front Hence the height of the pole depends on the situation In the situation shown below the pole should be at least 2 to 3 meters to avoid any obstacle The mounting kit can mount...

Страница 28: ...unded Please consult your location s building and electrical codes and follow them or consult standards such as National Electric Code The grounding screw is located at the bottom of A8n ac series as...

Страница 29: ...Altai Technologies Ltd All rights reserved Ethernet Connector Packet Installation The Ethernet connector packet includes the following components 1 Gasket 2 Housing 3 Screw Nut 4 Clamping Ring Gasket...

Страница 30: ...ies Super WiFi Base Station Installation Guide Altai Technologies Ltd All rights reserved Mount the housing screw nut and clamping ring Pass the housing and clamping ring through the cable and tight u...

Страница 31: ...at 6 Ethernet cable are recommended Maximum cable length between PoE adapter and A8n ac is 100m The end of cable RJ 45 modular jack pins are numbered 1 through 8 as shown _____________________________...

Страница 32: ...tallation Guide Altai Technologies Ltd All rights reserved The assignments of wire pairs to plug and jack pins are as follows Pin Pair wire Color 1 2 white orange 2 2 orange 3 3 white green 4 1 blue 5...

Страница 33: ...ildings It does not prevent lightning from striking but provides a means for controlling it and prevents damage by providing a low resistance path for discharge of the lightning energy 60 Protection C...

Страница 34: ...point of antenna is d the minimum height of the tip of lightning rod above the highest point of antenna H is recommended to be at least 2d such that a cone of protection of 60 degree is ensured aroun...

Страница 35: ...rnally For shielded Ethernet cable AC model or shielded POE cable DC model grounding the ground wire of the Ethernet POE cable should be connected to the screw port located at the inside bottom of low...

Страница 36: ...nd speed of lightning varies in different places the specifications of external lightning protectors should be chosen appropriately according to local protection requirements While this section gives...

Отзывы: