 IEC. All rights reserved.     All dimensions are nominal and subject to tolerances 

CONVERSION:  POWER TO LOCK <=> POWER TO OPEN  

Figure 4A

Figure 4B

WARNING:

Do not press on the keeper to release when the 
spring screw is not totally secured in position, this 
will cause damage to the spring barbell. When 
changing function, micro switch will spring out.

Procedures to convert Power to Open (Figure 

4B) to Power to Lock (Figure 4A):

Step 1:  Remove the two cover plate screws.
Step 2:  Remove the lock body from the cover 

housing.

Step 3:  Remove the spring screw from the end 

part of the strike body.

Step 4:  Remove the Barbell and replace in 

reverse position with long part in and short 
part out.

Step 5:  Replace the spring screw.
Step 6:  Refit the lock body into the cover housing 

and screw in the two cover plate screws. 

Procedures to convert Power to Lock (Figure 

4A) to Power to Open (Figure 4B):

Step 1:  Remove the two cover plate screws.
Step 2:  Remove the lock body from the cover 

housing. 

Step 3:  Remove the spring screw from the end 

part of the strike body.

Step 4:  Remove the Barbell and replace in 

position with short part in and long part 
out.

Step 5:  Replace the spring screw.
Step 6:  Refit the lock body into the cover housing 

and screw in the two cover plate screws.

ELECTRIC STRIKE MAINTENANCE

Maintenance should be carried out every 
6 months, or higher for heavy duty door 
traffic.
Electric strikes should be fitted exactly in 
accordance with the Alpro fixing 
instructions, ensuring and maintaining all 
relevant door gaps and clearances.
Under no circumstances use a spray 
lubricant, as this type of solvent can 
damage electronics. Electrical parts with 
the strike need no maintenance.
If required fit a protective diode as close 
to the coil as possible to protect the 

system from transient peaks

.

Ensure on a regular; basis the whole of the 
door system is checked (lock case, door 
closer, strike plate, handles etc.) to ensure 
the desired level of door operation and 

security is being maintained

.

PLEASE NOTE:

The warranty for the strike is void if:

The strike is assembled incorrectly
Parts fitted to the strike which are not 

approved Alpro Parts
The strike is incorrectly wired
There is incorrect voltage applied to the 

strike
Alpro electric strikes should be installed 

by suitably qualified engineers