Alpine eco-SPHERE PUR1400 Скачать руководство пользователя страница 5

4

For more information about our company or products, please visit our website at www.alpine4u.com or call us (USA) 1-877-710-0162

DISMANTLING AND REASSEMBLING

(Figure 2.2)

WARNING

:

 

Always unplug or disconnect all appliances in the pond from the electrical supply before installing, 

repairing, maintaining or handling the equipment in the water.

Dismantling (See Figure 2.1 on page 3):

A.  Follow the safety instructions. Unplug the power cord.

B.  Remove the top pre-filter cage (26) from the bottom pre-filter cage

        (15) by  opening the four clips (23).  Then push upper handle from the

        top pre-filter cage (26) towards the pump to release the cage.

        

See figure 2.2

C.  Remove the steel screw (8) from the cable clamp (22) to release

        the cord. 

D.  Remove two steel screws (8) from the upper bracket (21) and remove.

E.  Remove two steel screws (8) from the lower bracket (18) and remove.

F.  Remove the pond pump (20) with the pump casing from the bottom  

         pre-filter cage (15).

G.  Remove the four pump casing screws (19) and remove pump front

         cover (3).

H.  Remove the impeller (5) from the pump body (9). 

Important Note:

 

         The impeller magnet is powerful and will be pulled back towards

         the pump body (9) with great force.  Ensure your fingers do not get     

         clamped in the process. Pay attention to the O-ring (4), it will be attached

         to the pump body (9). 

I.  Clean all parts with clear water and a soft sponge or cloth. 

See figure 2.3

J.  Replace defective parts (if any).

Reassemble (See Figure 2.1 on page 3):

A.  Insert the impeller (5) back into the pump body (9) 

Important 

          Note:

 The impeller magnet is powerful and will be pulled back 

         towards the pump body (9) with great force.  Ensure your 

         fingers do not get clamped in the process. 

See figure 2.4

B.     Replace the O-ring (4) and properly fit to the pump body (9).

C.  Check whether the impeller (5) can rotate freely.

D.  Replace the pump front cover (3) on the pump body (9) and 

        then evenly tighten the four pump casing screws (19).

E.  Replace the pond pump (20) with the pump front cover (3) back    

        in to bottom pre-filter cage (15).

F.  Place the upper bracket (21) over the pond pump (20) securing    

         into the grooves.  Then screw two steel screws (8) into place.

G.  Place the lower bracket (18) over the pond pump (20).  Then 

         screw two steel screws (8) into place.

H.  Replace the cord into the cable clamp (22) and insert a steel 

        screw (8).

I.  Replace the top pre-filter cage (26) by pushing the upper handle into the bottom pre-filter cage (15)  clicking into place.  

         Then close the 4 clips (23).

J.  Restart the pump in water after properly reinstalling all the components.

(Figure 2.3)

(Figure 2.4)

Содержание eco-SPHERE PUR1400

Страница 1: ......

Страница 2: ...ver any replaceable filtering material supplied with the pump or filter as it is considered expendable Proof of purchase is required Warranty does not cover damage resulting from negligent handling mi...

Страница 3: ...low all safety instructions and all the important notices on the appliance before using the pump Failure to do so may result in loss of fish life and or damage to this appliance B Have a qualified ele...

Страница 4: ...er 4 O Ring 18 Lower Bracket 5 Impeller 19 4 Stainless Steel Screw 2 6 Ceramic Bearing 20 Pond Pump 7 Rubber Bearing 21 Upper Bracket 8 5 Stainless Steel Screw 1 22 Cable Clamp 9 Pump Body 23 4 Clips...

Страница 5: ...t force Ensure your fingers do not get clamped in the process Pay attention to the O ring 4 it will be attached to the pump body 9 I Clean all parts with clear water and a soft sponge or cloth See fig...

Страница 6: ...to enter the pump causing the pump to fail and voiding the warranty To protect your fish or other pond wildlife from being sucked into the pump it is highly recommended to not operate the pump withou...

Страница 7: ...ond circulation locate the pump as far away as possible from the location of the water running into the water feature It is recommended that the pump is NOT positioned in the deepest area of the pond...

Страница 8: ...ter A Remove the Pre filter cage from the pump B Place the pump below the water level next to the pond so that the water can flow into the pump this pump is not self priming C Turn the pump to the des...

Страница 9: ...eration This pump is suitable for use in water temperatures from 32 degrees Fahrenheit 0 degrees Celsius to 95 degrees Fahrenheit 35 degrees Celsius To keep the pump in long lasting working conditions...

Страница 10: ...C If none of the above solve your issue the impeller needs to be replaced 2 If your pump hums and doesn t push water A Pump or tubing may be clogged check area around pump to be sure there is no debr...

Страница 11: ...ting for PUR4100 includes 2 1 5 2 rotating Semi ball 1 5 plastic nut 2 hose fitting 2 1 5 2 O rings PUR5400C PUR FIT Fitting for PUR5400C includes 2 1 5 2 rotating Semi ball 1 5 plastic nut 2 hose fit...