Replacement Parts 

 *9UHX

Models 

 *9UHX060F12A2, *9UHX080J12A2, *9UHX080J16A2 & *9UHX100L20A2 (Natural Gas)        

*Denotes Brand

Replacement part supplied will be current active part.  For parts not listed, consult place of purchase.

Key

No.

Description

Functional

Part 

Number

*9UHX

060F12A

080J12A

080J16A

100L20A

1

Heat Exchanger, Primary

1012854

1

1012858

1

1

1012862

1

2

Heat Exchanger, Secondary

1174980

1

1174981

1

1

1174982

1

3

Motor, Blower

1172487

1

1174983

1

1172488

1

1172489

1

4

Mount, Motor kit

1014822

1

1

1014823

1

1

5

Wheel, Blower

1011420

1

1

1

1

6

Transformer

1172810

1

1

1

1

7

Capacitor, 10Mfd., 370V

1171729

1

1

               7.5Mfd., 370V

1171728

1

               40Mfd., 370V

1171982

1

8

Control, Fan Timer

1172550

1

1

1

1

9

Switch, Interlock

1171981

1

1

1

1

10

Switch, Pressure

1174984

1

1174985

1

1

1174986

1

11

Blower, Exhaust

1172823

1

1

1

1172824

1

12

Valve, Gas Nat.

1175705

1

1

1

1

13

Sensor, Flame

1172827

1

1

1

1

14

Igniter

1172533

1

1

1

1

15

Orifice, Burner #44 Nat.

1013797

3

4

4

5

16

Switch, Limit (Rollout)

1013103

2

2

2

2

17

Burner Assembly

1172965

1

1172966

1

1

1172967

1

18

Switch, Limit (Main)

1009169

1

1320361

1

1

1008445

1

*See Table below for bellyband location on motor

Bellyband Location 

on Motor

Model

A

*9UHX

inches

mm

060F12A2

1.38

35.1

080J12A2

1.81

46

080J16A2

1.81

46

100L20A2

1.65

41.9

Содержание 9UHX060F12A

Страница 1: ...6 Models Dual Certified 9UHX060F12A2 9UHX080J12A2 9UHX080J16A2 9UHX100L20A2 Denotes Brand Save This Manual For Future Reference 90 Furnace Upflow Horizontal International Comfort Products LLC Lewisbur...

Страница 2: ...s in wc Pa 3 2 797 2 9 722 1 9 473 2 0 498 3 2 797 2 9 722 1 9 473 2 0 498 3 2 797 2 9 722 2 3 573 2 4 598 3 3 822 2 9 722 Limits Controls Rollout Switch oF oC Limit Control Setting oF oC 350 177 250...

Страница 3: ...r inlet Airflow perfomance includes 1 25 4mm washable 600 FPM 3 0 m s max filter media 9UHX080J16 1 2 Denote Brand Exterrnal Static Pressure in wc Pa Speed Tap HI MED H MED L LO in wc Pa CFM L s CFM L...

Страница 4: ...47 440 01 1050 06 Specifications are subject to change without notice Wiring Diagram 9UHX...

Страница 5: ...ct to change without notice 48 Parts 9UHX O F F N O O F F N O O F F N O YY WW 15 N LL BB 12 11 18 V W R S T U J L JJ Q P Y X F UU VV TT SS H RR QQ KK 5 4 3 9 10 M K 2 1 B A 7 K 25 24 75a 2 FF CC 17 GG...

Страница 6: ...014823 1 1 5 Wheel Blower 1011420 1 1 1 1 6 Transformer 1172810 1 1 1 1 7 Capacitor 10Mfd 370V 1171729 1 1 7 5Mfd 370V 1171728 1 40Mfd 370V 1171982 1 8 Control Fan Timer 1172550 1 1 1 1 9 Switch Inter...

Страница 7: ...ker only 1173009 1 Comfortmaker only 1173010 1 1 Comfortmaker only 1173072 1 Heil only 1173012 1 Heil only 1173013 1 1 Heil only 1173075 1 Tempstar only 1172940 1 Tempstar only 1172946 1 1 Tempstar on...

Страница 8: ...CC Bottom Burner Box 1172848 1 1172849 1 1 1172850 1 DD Baffle Burner Box 1012338 1 1012339 1 1 1012340 1 EE Top Burner Box 1013702 1 1013703 1 1 1013704 1 FF Bracket Manifold Support 1012377 2 2 2 2...

Страница 9: ...535 1 1 1 1 Coupling Air Intake 1012284 1 1 1 1 Coupling Discharge 1002522 1 1 1 1 Bushing Strain Relief 1945287 1 1 1 1 Gasket Air Intake 1012583 1 1 1 1 Clamp Hose 5 8 1012975 4 4 4 4 Clamp Hose 3 4...

Отзывы: