![AlpicAir ACI/O-50HPR1 Скачать руководство пользователя страница 19](http://html1.mh-extra.com/html/alpicair/aci-o-50hpr1/aci-o-50hpr1_operation-and-installation-manual_2906604019.webp)
I nstallation notes
L ocation
Noise
T he air conditioner must be firmly installed and 3 4
liability checks must be done every year.
A void place whthin easy reach of young children.
Avoid other heat sources or direct sun light.
Install indoor unit away from T V set or radio.
A void where inflammable gas is likely to leak.
At salty coastal areas or special areas such as the vicinity
of a sulphurous hot spring,please contact dealer before
installation to make sure it is safe to use the unit.
Not to be installed in laundries.
T he air conditioner must be positioned so trat the plug
is accessible
Select a place with good ventilation or it may affect
performance or increase noise.
I nstall the air conditioner on a foundation that can
withstand its weight.insufficient strength may result in
the fall of equipment and cause injury.
Select a place so as not to annoy neighbor with the hot
air or noise.
Never place objects near the air outlet or the unit,it may
affect performance or increase noise.
If there is abnormal noise during the operating,contact
dealer immediately.
Installation and transportation
Wiring arrangement
Installation and transportation of the unit must be done
by skilled personnel.
B e sure to use only the specified accessories and parts
for installation,failure to use may lead to electric shock,
leakage or fire.
Carry out installation with consideration of strong winds,
typhoons,or earthquakes.Improper installation work may
result in accidents due to fall of equipment.
If the unit is to be moved to other place,please consult
dealer first.
Make sure wiring is carried out by qualified personnel
according to laws and regulations and this manual,using
a separate circuit and suitable fuse.
B e sure to install an earth leakage breaker.
Diameter of power supply cord must be big enough.
(R efer to P24 about the sizes of diameter)
If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
T he appliance shall be installed in accordance with
relative wiring regulations.
1. A ir-conditioner is the class I appliance, it must be use the suitable earthing connection.
2. Please do not cut or change the method of use of the yellow / green earthing wire of the
air-conditioner. Otherwise, it may cause the electrical leakage.
3. E arthing resistance should be approved by Country Standard GB 17790.
4. User power should be provided a reliable earthing terminal. Please do not let the earthing
wire to connect the following place:
1. Water supply
2. Gas supply
3. Sewage tube
4. Some places there are not reliable by a professional.
E arthing requirement
W ater pipe
Some parts of the water pipe are made of plastic
materials and not suitable for earthing.
G as pipe
I f there is electrical leakage accidently from air
conditioner,it is easy to cause fire or explosion.
The suction grille must be opened by skilled personnel.
In
st
al
la
ti
on
n
ot
es
17