15
T
R
O
U
B
L
E
S
H
O
O
T
I
N
G
SYMPTOM
CHECK POINT
CURE
No sound
Is the amplifier power LED illuminated?
1. Check fuses in amplifier
2. Check turn-on lead
3. Check signal leads
4. Check gain control
5. Check source unit volume
6. Clean contacts on fuse holders
Is the amplifier overload LED illuminated?
Check speaker for short or
amplifier for overheating
Check impedance with Ohm meter
If no reading, replace speaker
Check that the speaker moves freely
If speaker won’t move, replace speaker
Speaker is making a
Check that speaker is secured properly
Tighten mounting screws
rattling noise
and tightened with screws
Check enclosure construction
Check that the enclosure is debris free
Check speaker polarity
Correct polarity
No sound from one coil
Check speaker leads
1. Inspect for short circuits
2. Check for open connections
Reverse left and right speaker leads to
determine if it is occurring before the
speaker
Speaker is distorting at high
Check speaker load impedance capabilities
Confirm that the speaker load
volume levels
for the amplifier
impedance recommendations are
followed. Check the wiring
configuration of the speakers.
(To verify proper load impedance, use
an OHM meter to measure the total load
for each channel of the amplifier.
Verify that amplifier and/or crossover settings Select low-pass setting
are correct