![alphainnoTec WZS 41-101H/SX Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/alphainnotec/wzs-41-101h-sx/wzs-41-101h-sx_operating-manual_2906328025.webp)
25
We reserve the right to modify technical specifications without prior notice.
83063900cUK – Translation of the operating manual
© ait-deutschland GmbH
The initial filling and commissioning of the hot water
tank must be carried out by a qualified technician.
Ensure sure that…
•
the water supply to the domestic hot water tank
is open.
•
the domestic hot water tank is filled.
Operating manual of the heating and heat pump
regulator.
SAFETY TEMPERATURE LIMITER
A safety temperature limiter is built into the electric
heating element. Please check whether or not the reset
knob of this safety temperature limiter has jumped out.
If this is the case, push in the button.
1 Safety temperature button on
electric heating element
2 Reset knob
Dismantling
DANGER!
Risk of fatal injury due to electric shock!
Electrical connections may be installed
only by qualified electricians.
Before opening the unit, disconnect the
system from the power supply and secure
it from being switched back on!
WARNING!
Only qualified electrical technicians are
allowed to disconnect the unit from the
power supply and de-install all electrical
connections.
WARNING!
Only qualified heating or cooling system
technicians are allowed to remove the unit
from the system.
ATTENTION
The anti-freeze mixture of the heat source must
not be allowed to enter the sewer system.
Collect anti-freeze mixture and dispose of pro-
perly.
WARNING!
Only qualified cooling system technicians
are allowed to dismantle the unit and its
components.
ATTENTION
Recycle or provide for proper disposal of unit
components, refrigerants and oil in accordance
with the applicable regulations, standards and di-
rectives.
Содержание WZS 41-101H/SX
Страница 44: ......