ACX3100i Generator

Operation Manual

Effective: July 2013

Содержание ACX3100i

Страница 1: ...ACX3100i Generator Operation Manual Effective July 2013...

Страница 2: ...s fumes safety information to PREVENT INJURY OR DEATH to the technician or user WARNING FUMES HAZARD FIRE HAZARD WARNING provides flammability safety information to PREVENT INJURY OR DEATH to the tech...

Страница 3: ...erference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circu...

Страница 4: ...2 11 Output and Overload LEDs 17 2 12 DC Applications 18 2 13 Jump starting the generator 20 2 14 Low Oil Alarm System 20 2 15 Economy Switch 21 2 16 Stopping the Engine 21 2 17 Air Conditioning Oper...

Страница 5: ...ng 19 Figure 2 11 Low Oil Alarm LED Location 20 Figure 2 12 Economy Switch Location 21 Figure 2 13 Engine Switch Location 21 Figure 3 1 Example of Emission Control Tag 24 Figure 3 2 Temperature Range...

Страница 6: ...UMES FIRE HAZARD Do not operate the generator in rain or snow and do not let it get wet Generators are a potential source of electrical shocks when misused do not operate with wet hands WARNING ELECTR...

Страница 7: ...nerator Keep all accessories in a convenient location for future use or reference Battery Charge Kit Oil Jug Oil Drain Pipe Quick Start Guide Screwdriver Spare Spark Plug Spark Plug Wrench Figure 1 1...

Страница 8: ...ntenance panel is removed The bar code number label is found on the side of the generator near the fuel valve The bar code number is on the foil label on the shipping carton Please record this informa...

Страница 9: ...fill the oil well of the generator and use it for subsequent oil changes Running the engine with insufficient oil can cause serious engine damage The Low Oil Alarm System will automatically stop the e...

Страница 10: ...ethanol used If any undesirable operating symptoms appear while using a gasoline that contains ethanol replace it with a gasoline that has the proper blend CAUTION Use automotive unleaded regular gaso...

Страница 11: ...carburetor into the engine CAUTION 1 Loosen the maintenance cover screws and remove the maintenance cover 2 Remove the three air cleaner retaining screws Remove the cover and check the element Clean...

Страница 12: ...er grip lightly until resistance is felt then pull briskly out see Figure 2 3 Do not allow the starter grip to snap back Return it slowly by hand Do not let the starter rope rub against the generator...

Страница 13: ...rter for more than 10 seconds Repeat if necessary The maximum operating range is 75 based on a clear line of site Always place the remote switch on the control panel in the OFF position when not in us...

Страница 14: ...ous engine damage caused by an excessively lean air fuel mixture CAUTION 2 8 Operating at Extreme Temperatures High temperature adversely affects generator operation Generator performance will decreas...

Страница 15: ...ernal ground source Connections for standby power to Alpha equipment should only be made by authorized and qualified personnel Do not connect the generator to an automatic transfer device or severe da...

Страница 16: ...re in good working order before connecting them to the generator If the equipment begins to operate abnormally becomes sluggish or stops suddenly turn off the generator engine switch immediately Disco...

Страница 17: ...ove all electrical loads from the generator and investigate the cause of the overload 2 To reset the overload condition Red light stop and restart the generator The Green indicator light should be ill...

Страница 18: ...disconnect the vehicle s ground battery cable Reconnect the vehicle s ground battery cable after the charging cables are removed This procedure will prevent the possibility of a short circuit and spa...

Страница 19: ...The voltage regulator recharging the internal battery is designed for a maximum charge amperage of 12 13A so as long as the generator is running the internal battery should not be drained The generat...

Страница 20: ...ceptacle on the control panel 2 14 Low Oil Alarm System The low oil alarm system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase Before the oil level in t...

Страница 21: ...ch on the control panel to the OFF position In an emergency pushing the engine switch on the control panel to the OFF position will automatically stop the engine with or without a load However repeate...

Страница 22: ...tarted and is performing normally It is also important to follow the air conditioner manufacturer s instructions for starting and restarting for proper operation Some air conditioner manufacturers off...

Страница 23: ...tion Your engine has been designed to meet current Environmental Protection Agency EPA and the California Air Resources Board CARB clean air standards The regulations dictate that the manufacturer pro...

Страница 24: ...D THIS ENGINE IS CERTIFIED TO OPERATE ON UNEADED GASOLINE THIS ENGINE MEETS U S EPA CALIFORNIAAND EVP EMISSION REGULATIONS FOR SMALL OFF ROAD ENGINES FOR 2012 MODEL YEAR ENGINE FAMILY CYKXS 1251XG DIS...

Страница 25: ...nance cover and tighten the screws securely Recommended oil is SAE 15W 40 when ambient temperature is above 32 F 0 C SAE 0W 40 is recommended if operating temperatures are below 32 F 0 C Synthetic oil...

Страница 26: ...TION 1 Loosen the panel screws and remove the side maintenance panel 2 Remove three air cleaner retaining screws Remove the air cleaner cover and check the air cleaner element Clean or replace the ele...

Страница 27: ...Clean the spark plug with a wire brush if it is to be reused 7 Measure the plug gap with a feeler gauge 8 The gap should be 0 024 0 028in 0 6 0 7mm Correct by carefully bending the side electrode 9 In...

Страница 28: ...the generator Never use a spark plug with an improper heat range Always use an A7RTC resistor type spark plug Using a non resistor spark plug will interfere with AC output and the electronics and may...

Страница 29: ...issue unless you drop the arrester or the clamp or screws behind the grill Taking the grill off or leaving it on is a matter of your convenience but the procedure below will include removing the gril...

Страница 30: ...oxidation breakdown and the formation of gum and varnish and to inhibit corrosion in the fuel system and carburetor CAUTION 1 Be sure the storage area is free of excessive humidity and dust 2 It is be...

Страница 31: ...s will prevent the accumulation of varnish or sludge in the fuel system remove moisture from the generator windings Additionally the engine seals and moving components will be lubricated Exercise the...

Страница 32: ...take it to an authorized POWERHOUSE dealer NO YES Still no Spark YES YES NO NO Take the generator to an authorized POWERHOUSE dealer Is there enough oil in the engine Is the fuel valve open and the ig...

Страница 33: ...ess the overload reset button NO YES YES Is the circuit breaker ON Reset the circuit breaker NO Did pressing the overload reset button cause the appliance to operate NO NO Are there any defects in the...

Страница 34: ...5 4 No Output at the DC Receptacle 5 0 Troubleshooting 36 PH3100Ri OM Take the generator to an authorized POWERHOUSE service center Is the DC circuit breaker tripped Reset the circuit breaker YES NO 7...

Страница 35: ...witch off Ignition system T D I Spark plug A7RTC Starting system Remote Electric Recoil Fuel Automotive unleaded gasoline Lube oil synthetic or conventional SAE 15W 40 0W 40 below 32 Oil Capacity 33 8...

Страница 36: ...art or unit at its option Alpha may request defective parts to be returned Anything replaced under warranty becomes the property of Alpha To Obtain Warranty Service Do not return this generator to the...

Страница 37: ...ranted for two years If any emissions related part on your engine is defective the part will be repaired or replaced by The Coast Distribution System Inc Owner s Warranty Responsibilities As the SORE...

Страница 38: ...ystem and replaceable high altitude main jets Engine speed control system Economy Throttle Intake manifold Engine control module Evaporative Control System Fuel tank Fuel cap Fuel strainer Fuel valve...

Страница 39: ...on the battery d Never smoke or allow an open spark or flame in the vicinity of the battery or engine e Use charger for charging a lead acid battery only It is not intended to supply power to an extr...

Страница 40: ...he frame or engine block vii Connect charger ac supply cord to electric outlet and viii When disconnecting charger turn switches to off disconnect ac cord remove clip from vehicle chassis and then rem...

Страница 41: ......

Страница 42: ...667 8743 Alpha Technologies GmbH Hansastrasse 8 D 91126 Schwabach Germany Tel 49 9122 79889 0 Fax 49 9122 79889 21 Alphatec Ltd 339 St Andrews St Suite 101 Andrea Chambers P O Box 56468 3307 Limassol...