SAFETY INSTRUCTIONS 

 

READ THE SAFETY INSTRUCTIONS BEFORE STARTING THE INSTALLATION. 

• Not suitable for children under 6 years. (contains small parts which could be swallowed). 
• Do not run any cooling components without ensuring that cooling liquid is flowing through the cooling system. Coolers operated without coolant 
can become very hot. Caution: Burn Hazard! 
• Coolers that have no coolant flowing through them can destroy the computer hardware. W hen switching on the hardware, always make sure that 
the pump is working. 
• Please note when tightening the connectors or fittings, no tools such as screwdrivers, pliers, or wrenches should be used. All plastic products or 
metal threaded connections, which are linked with plastic parts, are easily over-loaded with tools. Cracking or other damages incurred in this way, 
as well as damage from leaking coolant, are not covered under the warranty! 
• Use only connectors with a sealing o-ring. When using a sealing ring a firm tightening with the hand is enough. Your instruction manual will 
clearly refer to the use of tools in exceptional cases. 
• If you have not done so yet, please check your hardware and cooling system (tightness, pump function and fans). This will minimize time spent 
searching for possible problems. ALPHACOOL INTERNATIONAL GMBH accepts no liability on the warranty of the manufacturer of the electronic 
components. The assembly of the cooling system takes place at your own risk. 
• The screws should not be tightened too firmly. If you tighten the screws excessively, the knurled nuts can loosen and the cooler´s uniform 
pressure is no longer guaranteed. 
• Fasten the connections of your choice to the cooler. Do not use tools such as wrenches for fastening the connections. Connectors with 8mm long 
threads may stop the flow. 
• We recommend a tightness test before assembling/installing the cooler. The water pressure in the water cooling loop can be  at a maximum of 
0.8 bar. DO NOT use tools on the connectors. 
• Ensure that the cooler is touching all components to be cooled through thermal grease and thermal pads. 
• Only use distilled water or ALPHACOOL CAPE KELVIN CATCHER in your cooling circuit. Damage caused by unsuitable coolant is not covered 
by the warranty! 
 

Specified normal operation 

All ALPHACOOL INTERNATIONAL GMBH cooling components are constructed and licensed for ALPHACOOL INTERNATIONAL GMBH 
computer construction parts. The warranty expires in case of misuse. 
 

Warranty 

1. Data, designs, illustrations, technical data, weight, measurement and specifications, contained in folders, catalogues, circulars, announcements 
or price lists, have a purely informative character. We do not undertake warranty for the correctness of these data. As to th e kind and the range of 
delivery, the data contained in the order and confirmation of order alone are decisive.  
 
2. If there is a lack of warrantor, you are entitled, on the basis of the legal regulations to require subsequent delivery, t o withdraw from the contract 
or reduce the purchase price. If you are a consumer, the limitation period of warranty claims for the supplied commodity amounts  to two years 
starting from receipt of goods (§ 13 BGB). If you are an entrepreneur, in accordance with legal conditions the limitation period amounts to only one 
year (§ 14 BGB). 
 
3. The warranty claim is valid only in combination with the original invoice, the sales slip or an ALPHACOOL confirmation on warranty claim. 
 
4. It is ALPHACOOL INTERNATIONAL GMBHs own discretionary authority to replace or repair the defective product or defective component. The 
replaced product or component changes into property of ALPHACOOL INTERNATIONAL GMBH.  
 
5. All warranty claims are accomplished by ALPHACOOL INTERNATIONAL GMBH or its authorized dealers. If the repair is carried out by a non-
authorized or assigned person, ALPHACOOL INTERNATIONAL GMBH does not take over either costs or liability, unless the repair has been 
previously agreed upon with ALPHACOOL INTERNATIONAL GMBH. 
 
6. All costs resulting from refitting of the products are not taken over by ALPHACOOL INTERNATIONAL GMBH. 
 
7. ALPHACOOL INTERNATIONAL GMBHs warranty excludes the following points: 
 

7.1. Regular controls maintenance and repair or the replacement of parts subject to regular wear and tear. 

 

7.2. Improper manipulation or defects caused by incorrect installation. 

 

7.3. Damages caused by storm, water, fire, overvoltage, acts of God, war, incorrect connection to the net, insufficient or incorrect 
ventilation or other reasons over which ALPHACOOL INTERNATIONAL GMBH has no influence. 
 
7.4. Damages resulting from transportation or improper packaging. 

 
8. Consumer´s rights are valid in the respective country; demands made to the salesman, as explained and laid down in the sal es contract, will not 
be covered by this warranty. ALPHACOOL INTERNATIONAL GMBH, its Branch Office and Distributors, are not responsible for direct  or indirect 
damage or losses, as far as the 
compelling legal regulations do not oppose it. 
 
9. ALPHACOOL INTERNATIONAL GMBH does not take over the warranty of the manufacturer of the electronic construction units and 
components. The assembly of the cooler takes place at your own risk. 
 

 

Contact an authorized waste management company in your 
country. A waste removal with the municipal waste (unsorted 
garbage) or similar mechanisms for the collection of local wastes 
is not permissible!

 

Содержание Eisstation 40 DC-LT-Reservoir

Страница 1: ...EISSTATION 40 DC LT RESERVOIR...

Страница 2: ...Eisstation 40 DC LT Reservoir Alphacool International GmbH 2...

Страница 3: ...UND INBETRIEBNAHME 10 ENGLISH 12 SAFETY INSTRUCTIONS 12 MOUNTING MATERIAL 13 TECHNICAL DETAILS 14 INSTALLATION 15 INSTALLATION OF THE PUMP 15 CONNECTING PUMP 15 MOUNTING TO THE RADIATOR 16 TUBING AND...

Страница 4: ...ten enthalten sind haben rein informativen Charakter Wir bernehmen keine Gew hr f r die Richtigkeit dieser Angaben Hinsichtlich der Art und des Umfangs der Lieferung sind allein die in Bestellung und...

Страница 5: ...International GmbH 5 MONTAGEMATERIAL EISSTATION 40 DC LT Reservoir Art Nr 15369 1x Ausgleichsbeh lter 2x M3x8 Schrauben 1x Sechskantschl ssel 3x Verschlussschrauben G1 4 1x Verschlussschrauben Tool 1...

Страница 6: ...4 IN 1x G1 4 OUT TECHNISCHE DETAILS Ma e in mm Die untere H lfte des Ausgleichsbeh lters kann abgeschraubt und um 180 gedreht werden Querschnitt A A Maximales Wasservolumen ca 28 7 ml Pumpenkompatibi...

Страница 7: ...MPE ANSCHLIE EN Die DC LT Pumpe wird ber einen 3 Pin Anschluss mit Strom versorgt Stecken Sie den Anschluss auf Ihr Mainboard auf Einige Mainboards verf gen ber spezielle Steckpl tze f r Pumpen Sollte...

Страница 8: ...nternational GmbH 8 MONTAGE AM RADIATOR Verschrauben Sie zuerst den Adapter 2x G1 4 Au engewinde drehbar am Radiator Verschrauben Sie nun den Ausgleichsbeh lter am Adapter 2x G1 4 Au engewinde drehbar...

Страница 9: ...Eisstation 40 DC LT Reservoir Alphacool International GmbH 9 MONTAGEM GLICHKEITEN...

Страница 10: ...n des Ausgleichsbeh lters entspricht OUT an Bef llen Sie nun den Ausgleichsbeh lter mithilfe eines Trichters durch den oberen Fillport Nutzen Sie das Verschlussschrauben Tool Wir empfehlen ausschlie l...

Страница 11: ...Verschlussschrauben Bef llen Sie nun den Ausgleichsbeh lter mithilfe eines Trichters durch den oberen Fillport Wir empfehlen ausschlie lich klare K hlfl ssigkeiten aus unserer eigenen Produktion CKC...

Страница 12: ...ders catalogues circulars announcements or price lists have a purely informative character We do not undertake warranty for the correctness of these data As to the kind and the range of delivery the d...

Страница 13: ...LT Reservoir Alphacool International GmbH 13 MOUNTING MATERIAL EISSTATION 40 DC LT Reservoir Art No 15369 1x reservoir 2x M3x8 screws 1x hexagon key 3x G1 4 plugs 1x plug key 1x adapter 2x G1 4 outer...

Страница 14: ...read inputs 4x G1 4 IN 1x G1 4 OUT TECHNICAL DETAILS Dimensions in mm The lower half of the reservoir can be unscrewed and turned by 180 Section A A Max capacity approx 28 7 ml Pump compatibility The...

Страница 15: ...to the bottom of the reservoir CONNECTING PUMP The DC LT pump is supplied with power via a 3 pin connector Plug the connector onto your mainboard Some mainboards have special 4 pin sockets for pumps I...

Страница 16: ...ol International GmbH 16 MOUNTING TO THE RADIATOR First screw the adapter 2x G1 4 outer threads rotatable to the radiator Now screw the reservoir to the adapter 2x G1 4 outer threads rotatable 1 2 ada...

Страница 17: ...Eisstation 40 DC LT Reservoir Alphacool International GmbH 17 MOUNTING OPTIONS...

Страница 18: ...to IN and the inlet of the reservoir equivalent to OUT Then fill the Eisstation 40 DC LT Reservoir with a funnel through the upper fillport Use the plug key We only recommend clear coolants from our...

Страница 19: ...inlets using the 3 screw plugs Now fill the Eisstation 40 DC LT Reservoir with a funnel through the upper fillport We only recommend clear coolants from our own production CKC or Eiswasser Crystal no...

Страница 20: ...e en faveur de la justesse de ces informations Concernant le type et volume de la livraison seulement les informations contenues dans la commande et la confirmation de la commande sont d cisives 2 En...

Страница 21: ...voir Alphacool International GmbH 21 CONTENU DE L EMBALLAGE EISSTATION 40 DC LT Reservoir Art n 15369 1x r servoir 2x vis M3x8 1x cl hexagonale 3x bouchons G1 4 1x outil de bouchon 1x adaptateur 2x fi...

Страница 22: ...G1 4 IN entr e 1x G1 4 OUT sortie FICHE TECHNIQUE Dimensions en mm La moiti inf rieure du r servoir peut tre d viss e et tourn e de 180 Coupe transversale A A Capacit maximale approx 28 7 ml Compatibi...

Страница 23: ...voir CONNEXION DE LA POMPE La pompe DC LT est aliment e en courant via un connecteur 3 broches Branchez le connecteur sur votre carte m re Certaines cartes m res ont des prises sp ciales 4 broches pou...

Страница 24: ...l International GmbH 24 FIXATION AU RADIATEUR Vissez d abord l adaptateur 2x filetage G1 4 m le rotatif sur le radiateur Vissez ensuite le r servoir sur l adaptateur 2x filetage G1 4 m le rotatif 1 2...

Страница 25: ...Eisstation 40 DC LT Reservoir Alphacool International GmbH 25 VARIANTES DE MONTAGE...

Страница 26: ...et celle du r servoir correspond OUT sortie Maintenant remplissez le r servoir avec un entonnoir par l ouverture sur le c t Utilisez l outil de bouchon Nous conseillons uniquement l utilisation de liq...

Страница 27: ...e des 3 bouchons Maintenant remplissez le r servoir avec un entonnoir par l ouverture sur le c t Nous conseillons uniquement l utilisation de liquides clairs de notre production CKC ou Eiswasser Cryst...

Страница 28: ...r Str 1 38122 Braunschweig Support 49 0 531 28874 0 Fax 49 0 531 28874 22 E Mail info alphacool com General Manager Fabian Noelte WEEE Reg Nr DE 544444 Trade Register Amtsgericht Braunschweig HRB 2023...

Отзывы: