background image

English 

Eisbecher 2 Aurora Glas 

Alphacool International GmbH 

10 

English

 

Safety Instructions 

Read the safety instructions before starting the installation. 

Assembly material 

 

 

 

 

 

 

 

 

 

 

 

The 140mm riser pipe 
is only included in the 

Eisbecher Aurora 

250mm.

 

 

4x M3x5 

12x M4x8 

4x M4x12 

4x M4 

2x Fan bracket 

1x riser pipe 140mm 

2x 120 Fan bracket 

 

 

 

 

 

 

 

 

 

 

 

 

 

3x                  

Screw plug 

1x                      

Allen key 

1x                   

Screw plug 

 Tool 

2x                    

Stand Bracket 

1x                   

pump mounting 

1x                           

O-Ring 53x3,5 

  1x                       

Digital RGB adapter 

 

 

 

Содержание Alphacool Eisbecher Aurora D5

Страница 1: ...AGB Alphacool Eisbecher Aurora D5 Acetal Glas ...

Страница 2: ...shinweise 4 Montagematerial 4 Montage Eisbecher 2 Aurora Glas 5 Towermontage 6 Radiatormontage 7 Anschluss Möglichkeiten 8 aRGB Anschluss 9 English 10 Safety Instructions 10 Assembly material 10 Assembly Eisbecher 2 Aurora Glas 11 Tower assembly 12 Radiator assembly 13 Connection options 14 aRGB Connection 15 Français 16 ...

Страница 3: ...onal GmbH Eisbecher 2 Aurora Glas 3 avis général de sécurité 16 Matériel de Assemblée 16 Assemblée Eisbecher 2 Aurora Glass 17 Assemblage de logements 18 Montage de radiateurs 19 Options de connexion 20 Connexion aRGB 21 ...

Страница 4: ... Installation beginnen Montagematerial Das Steigrohr 140mm liegt nur im Eisbecher Aurora 250mm bei 4x M3x5 12x M4x8 4x M4x12 4x M4 2x Lüfterhalterung 1x Steigrohr 140mm 2x 120 Lüfterhalterung 3x Verschlussschraube 1x Innensechskant 1x Verschluss Tool 2x Standhalterung 1x Pumpenhalterung 1x O Ring 53x3 5 1x Digital RGB adapter ...

Страница 5: ...n an die Montageklammern Anschließend können Sie das System an jedem beliebigen 120mm oder 140mm Lüfter und Radiatorplatz anbringen Steigrohr Positionen Entfernen Sie die Pumpe und Standhalterung schrauben Sie die hier rot markierten Halterschrauben raus Ziehen Sie den Deckel mit Gestänge und anschließend das Glasrohr vorsichtig heraus Wechseln Sie das gewünschte Steigrohr aus Das Steigrohr wird G...

Страница 6: ...e darauf dass der Filter mit dem Inlay immer oben links positioniert ist Nur in dieser Position ist der Wasserfluss gewährleistet Towermontage Nutzen Sie dafür die vier M4x8 Schrauben inVerbindung mit den M4 Muttern Je nach Gehäusetyp ergeben sich weitere Befestigungsmöglichkeiten ...

Страница 7: ...wenden Sie für die Radiatormontage die vier M3x5 Schrauben Beachten Sie das je nach Radiatorgröße wie im Beispiel 240 30 und 280 30 X Flow die Halterung gedreht werden muss Radiator Beispiel 120 30 und 140 30 X Flow Bei diesem Beispiel brauchen die Halter nicht gedreht werden ...

Страница 8: ...piele zeigen einige Möglichkeiten auf Verschließen Sie alle Öffnungen welche Sie nicht benötigen mit derVerschlussschraube Wir empfehlen ausschließlich klare Kühlflüssigkeiten aus unserer eigenen Produktion CKC Tec Protect oder Eiswasser Crystal kein UV oder reines destiliertes bzw Osmose gefiltertesWasser zum auffüllen Fillport Fillport ...

Страница 9: ...Alphacool International GmbH Eisbecher 2 Aurora Glas 9 aRGB Anschluss Optional Alphacool Aurora Eiscontrol Art Nr 15360 SATA Power Anschluss Eisbecher 2 Aurora Glas ...

Страница 10: ...efore starting the installation Assembly material The 140mm riser pipe is only included in the Eisbecher Aurora 250mm 4x M3x5 12x M4x8 4x M4x12 4x M4 2x Fan bracket 1x riser pipe 140mm 2x 120 Fan bracket 3x Screw plug 1x Allen key 1x Screw plug Tool 2x Stand Bracket 1x pump mounting 1x O Ring 53x3 5 1x Digital RGB adapter ...

Страница 11: ... brackets to the mounting brackets with the four M4x12 screws You can then attach the system to any 120mm or 140mm fan and radiator space Rising pipe positions Remove the pump and stand bracket unscrew the holder screws marked in red Carefully pull out the cover with linkage and then the glass tube Replace the desired riser tube The riser tube is plugged in ...

Страница 12: ...ition Make sure that the filter with the inlay is always positioned on the top left Only in this position is the water flow guaranteed Tower assembly Use the four M4x8 screws in conjunction with the M4 nuts Depending on the enclosure type there are further fastening options ...

Страница 13: ...tor assembly Use the four M3x5 screws for mounting the radiator Note That depending on the radiator size as in the example 240 30 and 280 30 X Flow the bracket must be rotated Radiator example 120 30 and 140 30 X Flow In this example the holders do not need to be rotated ...

Страница 14: ... Reservoir as you wish The examples show some possibilities Close all openings that you do not need with the screw plug We recommend only clear cooling liquids from our own production CKC Tec Protect or Eiswasser Crystal no UV or pure distilled or osmosis filtered water for refilling Fillport Fillport ...

Страница 15: ...Alphacool International GmbH Eisbecher 2 Aurora Glas 15 aRGB Connection Optional Alphacool Aurora Eiscontrol item no 15360 SATA Power Connection Eisbecher 2 Aurora Glas ...

Страница 16: ...ion Matériel de Assemblée La tube montante de 140 mm est uniquement incluse dans le Eisbecher Aurora de 250 mm 4x M3x5 12x M4x8 4x M4x12 4x M4 2x Support de ventilateur 1x Tube montant 140mm 2x 120 Support de ventilateur 3x Bouchon à vis 1x Douille hexagonale 1x Bouchon à vis outil 2x support de fixation 1x support de pompe 1x O Ring 53x3 5 1x Digital RGB adapter ...

Страница 17: ...ers de montage avec les quatre vis M4x12 Vous pouvez ensuite monter le système à n importe quel emplacement de ventilateur et de radiateur de 120 mm ou 140 mm Positions de la colonne montante Retirez la pompe et les pieds dévissez les vis marquées en rouge ici Retirez avec précaution le couvercle avec la tringlerie puis le tube de verre Remplacez le tube montant désiré Insertion du tube montant ...

Страница 18: ...lez à ce que le filtre avec l incrustation soit toujours placé en haut à gauche Ce n est que dans cette position que le débit d eau est garanti Assemblage de logements Utilisez les quatre vis M4x8 en conjonction avec les écrous M4 Selon le type de logement il existe d autres options de montage ...

Страница 19: ...ilisez les quatre vis M3x5 pour le montage du radiateur Veuillez noter qu en fonction de la taille du radiateur le support doit être tourné comme dans l exemple 240 30 et 280 30 X Flow Exemple de radiateur 120 30 et 140 30 X Flow Dans cet exemple les supports n ont pas besoin d être tournés ...

Страница 20: ... montrent quelques possibilités Fermez toutes les ouvertures dont vous n avez pas besoin avec le bouchon à vis Nous ne recommandons que des liquides de refroidissement clairs issus de notre propre production CKC Tec Protect ou Eiswasser Crystal pas d UV ou de l eau pure distillée ou filtrée par osmose pour le remplissage Fillport Fillport ...

Страница 21: ...Alphacool International GmbH Eisbecher 2 Aurora Glas Français 21 Connexion aRGB Optionnel Alphacool Aurora Eiscontrol point n 15360 SATA Power Connexion Eisbecher 2 Aurora Plexi ...

Страница 22: ... GmbH Marienberger Str 1 38122 Braunschweig Support 49 0 531 28874 0 Fax 49 0 531 28874 22 E Mail info alphacool com General Managers Andreas Rudnicki Nathanael Draht Fabian Noelte WEEE Reg Nr DE 544444 Trade Register Amtsgericht Braunschweig HRB 202390 VAT ID Nr DE27058421 Tax number 13 207 02047 ...

Отзывы: