900-0117-01-00 Rev C 

29 

Operation 

The MATE3 provides the means for programming OutBack inverter/chargers, charge controllers, and 
battery monitors when preprogrammed default settings do not work for the destined installation. 

 

IMPORTANT:   

The OutBack inverters have nonvolatile memory and will retain any settings 
that have been changed, even after the MATE3 is removed.  If a system does 
not have a MATE3, an installer can bring a MATE3 to the site temporarily, 
install it, change the settings, and then remove it.

 

 

IMPORTANT:   

Some functions are not based in the inverter or charge controller, but are 
part of the MATE3’s firmware.  They will not function if the MATE3 is 
removed.  These functions are listed beginning on page 115.   

 

Display and LED Status Indicators 

 

Figure 18 

Display and LED Status Indicators 

Battery Status LEDs (x3)

LCD Screen 

Inverter LED 

Charger LED 

Generator LED 

Events LED

AC Input LED

Favorite LED

Network Status LEDs

1

(located on back) 

1

Solid yellow indicates the ethernet link is established.

Blinking green indicates network activity. 

Abbreviated Manual for Mate 3

Prepared by Miller Solar

For emergencies: 805-438-5600

We have deleted unnecessary information so you do not need to read more than the 
minimum, enhancing your understanding of the really important points.  We will provide 
training on the use and maintenance of your system.

if you wish to learn more about your Mate3 and associated equipment, please refer to the 
complete manual sets.

Below is an overview of the Mate 3 controller.  The unit will allow you to read critical values 
on your power system, make some adjustments and initiate important operations, such as 
starting the generator or starting an equalization charge (see attached battery instructions). 

Содержание OutBack POWER MATE3

Страница 1: ...se of problems we can talk you through most problems over the telephone William Miller 805 438 5600 william millersolar com The most important thing is to take care of your batteries We will provide i...

Страница 2: ...epared by Miller Solar For emergencies 805 438 5600 The picture above shows the Mate 3 with the lower cover off There are no routine operations that require you remove this cover Some users may want t...

Страница 3: ...play and LED Status Indicators Battery Status LEDs x3 LCD Screen Inverter LED Charger LED Generator LED Events LED AC Input LED Favorite LED Network Status LEDs1 located on back 1 Solid yellow indicat...

Страница 4: ...cannot be changed Voltages higher than shown in the GREEN row usually means that the batteries are charging Inverter LED green This LED is located on the INVERTER hot key See page 55 It provides a vi...

Страница 5: ...or or warning messages are defined in the inverter Operator s Manual AC Input LED yellow This LED is located on the AC INPUT hot key See page 62 It provides a visual reference for the status of the AC...

Страница 6: ...GRID TIED...

Страница 7: ...RTER Hot Key Screen Items Mode displays the setting selected by the soft keys ON OFF or Search Battery displays the battery voltage not compensated for temperature See page 41 for the compensated valu...

Страница 8: ...bring up several recommendations and confirmations to ensure this function is not started accidentally Soft Key Options Back returns to the Home screen Bulk Charge advances to the Bulk Charge screen...

Страница 9: ...ge is reached Equalize right side of screen displays whether this mode is enabled or disabled Last EQ charge displays the date and time for the most recent equalization cycle Soft Key Options Back ret...

Страница 10: ...ing the generator it reads OFF If active it may read STARTING or RUN Fault displays the message AGS Fault if the generator voltage is lost Otherwise it displays NONE Last Run displays the reason of th...