Alpha Easy-Stat 7.2000050 Скачать руководство пользователя страница 6

 

Turn the knob and 6 and 7 will be underlined 

 (Saturday and Sunday), press the knob to 

enter the heating on/off time periods. The display will show a graph at the top 

 

representing each hour of the day and the time from midnight, turn the knob to scroll through 

the hours of the day and press the transmit button 

 to select an on period, this will be 

identified by a solid block in the graph for each hour selected. To remove a selected on period 

press the temperature button 

 and the solid block will disappear. Press the knob to store the 

settings. 

Turn the knob and day one will flash; this gives the option to set different heating on/off 

periods for individual days if required 

. To set each day follow the procedure above for 

each day. If different individual day settings are not required turn the knob through each day 

to skip to the next function. 

After the heating on/off periods are set turn the knob and 

 will be displayed, this 

represents the minimum room temperature setting during a heating off period. Press the knob 

to enter the menu and turn the knob to adjust the temperature to the desired setting (e.g 

14⁰C), press the knob to store.  

Turn the knob and 

 will appear, press the knob to exit the programming menu. 

Alternatively it will automatically exits after 1 minute. 

Parameter settings 

Frost Protection 

Frost protection will switch the heating on should the room temperature fall below the 

temperature set (e.g. 4⁰C) to help prevent pipes from freezing. 

Press the temperature button  

 for 5 seconds and FrSt 01 will appear, press the rotary knob 

to enter menu and the temperature will appear.

 

Turn the knob to set the temperature and 

press the knob to store. 

 

Heating off  

This setting controls the switch off point for the heating to maintain an even temperature e.g. 

if the set temperature is 20⁰C and the heating off setting is 0.6, the heating will switch off 

when the room temperature reaches 20.6⁰C. 

Turn the knob to HOFF 02, press the knob and the temperature will be displayed, turn the 

knob to adjust the temperature and press the knob to store. 

 

 