The boiler has a built in frost protection function to protect the boiler (only) from freezing. If water within the boiler falls below 
4°C the boiler will fire in heating mode and raise the temperature of the heating water (in the boiler only) to 30°C.
For this function to be active the gas and electricity supplies to the boiler must be turned on and the boiler be in either 
'Standby' or 'On' mode.
Further protection for the mains water supply and heating circuit must be provided separately.
If Alpha external controls are fitted, a frost protection setting is incorporated into the room thermostat activating the central 
heating when the temperature falls below 5°C. 

5  FROST PROTECTION

6  CONDENSATE DRAINAGE

High efficiency (condensing) boilers remove more useful heat from the combustion gases, resulting in additional water vapour 
which is collected within the boiler (as condensate) and run to a suitable drainage point via the condensate drainage pipe.
Where possible the condensate drain should be connected internally to a waste pipe within the property to prevent the risk of 
freezing.
If the condensate drain pipe runs outside it should be fitted with increased diameter pipe and be suitably lagged to reduce 
the risk from freezing.
In situations where there are likely to be extremes of temperature or wind-chill the use of a proprietary trace-heating system 
for external condensate drainage pipework, incorporating an external frost thermostat, should be considered.

7  GAS SAFETY REGULATIONS

Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, i.e. Gas Safe registered personnel. 
Failure to install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure 
compliance with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Checklist must be fully completed by the installer on installation of the boiler. The Benchmark Checklist is 
shown in back of the Installation and Servicing instructions. All Gas Safe registered installers carry a Gas Safe ID card and 
have a registration number. Both should be recorded in the Checklist. You can check your installer is Gas Safe registered by 
calling Gas Safe on 0800 408 5500.

It is a requirement that the boiler is installed and commissioned to the manufacturers instructions and the data fields on the 
commissioning checklist completed in full.

To instigate the boiler guarantee the boiler needs to be registered with the manufacturer within one month of the installation.

To maintain the boiler guarantee it is essential that the boiler is serviced annually by a Gas Safe registered engineer who has 
been trained on the boiler installed. The service details should be recorded on the Benchmark Service Interval Record and 
left with the householder.

8  BENCHMARK COMMISSIONING and SERVICING

Содержание E-Tec 28

Страница 1: ...venoaks Kent TN15 7RS For Technical help or for Service call ALPHA HELPLINE Tel 0844 871 8764 website www alpha innovation co uk Set for use with Natural Gas Leave these instructions with the User These instructions have been carefully prepared but we reserve the right to alter the specification at any time in the interest of product improvement Alpha Therm Limited 2017 ...

Страница 2: ...res are still active Off In this mode there is electrical power to the boiler but the boiler will not function in any condition On In this mode the boiler can be switched between Summer or Winter settings by pressing the Mode button item 1 in Fig 1 Summer setting The boiler will only provide hot water when a tap is turned on and the central heating will not activate even if requested by external c...

Страница 3: ...and temperature will still be maintained according to the setting of the room thermostat 3 HEATING AND HOT WATER TEMPERATURE Fig 2 External weather compensation probe fitted Flow temperature C External temperature C 27 15 5 5 10 0 10 15 20 25 25 60 40 85 50 Flow temperature in brackets ie 25 to 50 C range when boiler is used with a low temperature system such as under floor heating Setting 1 to 9 ...

Страница 4: ...tem for external condensate drainage pipework incorporating an external frost thermostat should be considered 7 GAS SAFETY REGULATIONS Current Gas Safety Installation and Use Regulations It is the law that all gas appliances are installed and serviced by a competent person i e Gas Safe registered personnel Failure to install or service appliances correctly could lead to prosecution It is in your i...

Страница 5: ...lt or gas leak is suspected turn off the gas supply Do not touch any electrical switches do not smoke and extinguish all naked flames Contact the National Gas Emergency Service immediately on 0800 111 999 8 ELECTRICAL SUPPLY The boiler requires a 230 240 V 50 Hz supply fused at 3 A To connect a plug The colour of the wires in the mains lead of the boiler may not correspond with the coloured markin...

Отзывы: