15
GROUND FAULT CIRCUIT INTERRUPTER:
A Ground Fault Circuit Interrupter (GFCI) is mounted at the end of power supply cord. The
GFCI goes OFF when water enters inside the tool’s housing preventing the operator from
electric shocks.
DANGER!
When the GFCI goes OFF, the Reset button pops up. This is
the result of water entering the polisher housing. Turn OFF the
power switch and blow dry air inside the motor cover through
the air vents. Press the GFCI Reset button. The polisher is
ready to start working after the reset button is pressed down.
(Figure-6)
WARNING!
1. Do not remove the GFCI.
2. Check items below when the GFCI goes OFF frequently.
• Force applied on the polisher.
• Water entered inside the polisher.
• Voltage drop due to sharing the same power source in work area.
MAINTENANCE AND INSPECTION
DANGER!
Before servicing the polisher, turn the switch OFF and unplug the power supply
cord from the power outlet.
1. Check the attaching screws.
– Before starting any operation, inspect polisher for loose screws.
– If the polisher is used with loose screws, it is dangerous. Be sure to tighten them.
Reset
Test
Figure-6