PARTS IDENTIFICATION

2

3

External Part Identification

Internal Part Identification

1

2

3

4

5

6

7

11

12

1.   Mild Steel Casing
2.   Enamel Coating Tank
3.   Polyurethane Insulation
4.   Heating Element
5.   Hot Water Pipe
6.   Cold Water Pipe

7.   Anti-corrosion Anode Rod
8.   Thermal Cut-out
9.   Thermostat
10. Maintenance Cover
11. Terminal Block
12. Mounting Bracket

8

1.   Power Indicator
2.   Heating Indicator
3.   Isolation Barrier
4.   Pressure Relief Valve
5.   Discharge Pipe
6.   Temperature Control Knob
7.   Hot Water Outlet
8.   Cold Water Inlet
9.   Mounting Bracket (2 pcs)
10. U-shape Mounting Bracket (2 pcs)
11. Expansion Bolt (4 pcs)
12. L-shape Expansion Bolt (2 pcs)
13. Screw (8 pcs)
14. PVC Hose

1

2
3
4

5

6

3

7

8

PARTS IDENTIFICATION

9

10

11

12

13

14

10

9

Содержание AST-30-H

Страница 1: ...Version 2022 V1 Electric Storage Water Heater AST 30 H AST 40 H AST 50 H AST 60 H AST 70 H AST 80 H AST 90 H USER MANUAL...

Страница 2: ...st be installed with a mono directional Pressure Relief Valve at the inlet pipe The pressure relief device is to be operated regularly to remove lime deposit and to verify that there is no blockage Th...

Страница 3: ...ermal Cut out 9 Thermostat 10 Maintenance Cover 11 Terminal Block 12 Mounting Bracket 8 1 Power Indicator 2 Heating Indicator 3 Isolation Barrier 4 Pressure Relief Valve 5 Discharge Pipe 6 Temperature...

Страница 4: ...ed Conductor Size Fuse MCB On Off Switch 240V 50 60 Hz 3 0 kW 12 5 A 4 0 mm2 20 A 20 A 4 5 Water The unit is built to operate at both high and low household water pressures and is capable of supplying...

Страница 5: ...unting Guide Diagram Wall Mounting Right Side Concrete Wall Mounting Bracket Mounting Bracket Concrete Wall Mounting Bracket Mounting Bracket Maintenance Cover rotate 180o before mounting Wall Mountin...

Страница 6: ...This pipe must be left open to the surrounding air b Connect the outflowing hot water line to the outlet of the heater Red c Connect a PVC Hose to the Discharge Pipe of the Pressure Relief Valve at on...

Страница 7: ...Power Bulb Green To Heater Chasis TECHNICAL SPECIFICATIONS Electrical Loading 3 0 kW 240V 50 60 Hz Working Pressure min 0 02 MPa 0 2 bar max 0 8 MPa 8 0 bar Water Connection 15mm dia 1 2 BSP Water Tem...

Страница 8: ...e Solution Indicator light does not light up 1 The power source is not connected or badly connected 2 Indicator failure 3 Thermostat cut off Get a professional technician to check the electrical wirin...

Страница 9: ...r 71 Jalan Molek 3 10 Taman Molek 81100 Johor Bahru Tel 07 353 4833 4933 Fax 07 355 4233 Melaka 19 19 1 19 2 Jalan KSB 11 Taman Kota Syahbandar 75200 Melaka Tel 06 292 2398 2399 Fax 06 292 2392 Perak...

Отзывы: