3
Alpha CombiMax 350 and 600
2
TECHNICAL DATA
8 bar
0.1 bar
15 mm
15 mm
35 L
60 L
4 L at 2.5 bar
5 L at 2.5 bar
2.5 bar
90°C/7 bar
4 bar
18.0
4.0
56
133
7.25 mins
12 mins
4.0 mins
7 mins
Domestic Hot Water
Max. Mains Inlet Pressure
(inlet of pressure reducing valve)
Min. Mains Water Pressure
Mains Inlet Connection
DHW Outlet Connection
DHW Storage
(350 model)
(600 model)
Expansion Vessel Size (pre-charge press.)
(350 model)
(600 model)
Pressure Reducing Valve Setting
Temperature and Pressure Relief Valve
Expansion Relief Valve Setting
Flow Rate
L/min
G.P.M.
Outlet Water Temp. (Approx.)
°C
°F
Time to raise water storage 50°C (350 model)
(600 model)
Reheat time for 70% of storage
(350 model)
(600 model)
Min. Clearances required for Servicing
Top
Bottom
Sides
Front
Dimensions CombiMax
Height
(350 model)
Width
(600 model)
Width
Depth
Overall width when fitted with boiler
(350 model)
(600 model)
Lift Weight of Store
(350 model)
(600 model)
Weight Full and Operational
(350 model)
(CombiMax and Boiler)
(600 model)
2.2
INSTALLATION
Supply
External Fuse
Power Consumption
230/240 V ~ 50 Hz
3 A
90 W
2.3
ELECTRICAL
2.1
DOMESTIC HOT WATER
2.4
ELECTRICAL CONNECTIONS
Note: This Appliance Must Be Earthed
Boiler terminal block
CombiMax terminal block
220 mm
250 mm
5 mm
450 mm
950 mm
270 mm
365 mm
360 mm
720 mm
815 mm
12 kg
25 kg
92 kg
130 kg
Supply
External Fuse
Power Consumption
230/240 V ~ 50 Hz
10 A
2 kW
Alpha Immersion Heater (optional)