![Alpha Alpha CD35C Скачать руководство пользователя страница 2](http://html1.mh-extra.com/html/alpha/alpha-cd35c/alpha-cd35c_installation-manual_2905125002.webp)
STEP 1
STEP 2
STEP 3
STEP 4
STEP 5
STEP 6
Using a spirit level, tape the GasSaver and
PremierPack templates to wall. Mark all positions as
indicated on wall, drill holes and add rawlplugs. Mark
flue position and drill hole.
Screw PremierPack, GasSaver hanging bracket and
top fixing bolt assembly to wall.The boiler and
GasSaver can now be simply hung whenever you are
ready.
Drill hole in wall and push Expansion Relief Valve pipe
through. Pull back so that the rubber grommet
completes a seal, mark off and cut to required length.
Remove tails from boiler and screw to PremierPack.
Measure, cut, bend and fit GasSaver mains inlet/outlet
pipework to PremierPack using the pipe clip plate.
Complete any other necessary pipework and fit using
pipe clips where required.
Complete any soldering that is necessary
Position thermal store where required, and fit
washers plus tails to connections shown on pipework
label on top of store
The perfect combination
18 steps to 18 litres/minute
FlowSmart system v 200L unvented cylinder at flow rate 18 litres/minute
Time (minutes)
T
e
m
p
°C
a
t
fl
o
w
ra
te
1
8
L
/m
in
DHW output °C
200L unvented cylinder
DHW output °C
FlowSmart 25L store
80
70
60
50
40
30
20
10
0
2
4
6
8
10
12
14
16 18
20
DHW output °C
FlowSmart 50L store
FlowSmart system v 200L unvented cylinder at flow rate 18 litres/minute
Its thermal store recharges in just 5-7
minutes, compared to the 45 minutes a
200 litre cylinder can take to replenish
from empty.
The small thermal store takes up much
less space than a cylinder, enabling
FlowSmart to be more easily sited. If
required, the entire system can even be
installed together in a cupboard.
This, along with a limited pipework
requirement, means installation of
FlowSmart is also quicker and simpler.
25
%
LESS GAS USED*
FlowSmart uses up to 25% less gas to provide DHW than a system boiler with a 200 litre unvented store
and consumes less electricity.
By incorporating a GasSaver and small thermal store, FlowSmart allows a combi boiler to deliver a flow rate of 18
litres of hot water per minute, at 50ºC or above, for up to 30 minutes – more than three times longer than a typical
system boiler set-up.Together with its superior energy efficiency and ease of installation, this makes FlowSmart the
perfect combination.