DESCRIPTION

The Alpha Range of boilers are wall mounted, fan assisted room-sealed combination boilers, providing both central heating and
domestic hot water at mains pressure.

The Alpha 240E and 240P boilers are suitable for central heating loads of between 9.3 and 23.3 kW (31 700 and 79 500 Btu/h). The
Alpha 280E and 280P boilers are suitable for central heating loads of between 9.3 and 28 kW (31 700 and 95 500 Btu/h).

The boilers will provide central heating (as required) during the 'on' times set on your clock (if fitted). Hot water is always
available whenever a hot tap is opened and takes priority over the central heating.

Note: The Alpha 240P and 280P use a permanent pilot for lighting the burner, and the Alpha 240E and 280E burner is lit
electronically.

2

USER CONTROLS

Pull the controls panel cover forward and down to gain access to the controls.

Fig. 1

Clock
(if fitted)

System
Pressure
Gauge

Central
Heating
Thermostat

Domestic
Hot Water
Thermostat

Selector
Switch

Gas
Control

Indicator
Neons

Pilot and Burner
Viewing Window

0

THERMOSTAT

0

THERMOSTAT

SELECTOR

GAS

OFF

bar

0

4

3

2

1

Alpha 240P and 280P

Clock
(if fitted)

System
Pressure
Gauge

Central
Heating
Thermostat

Domestic
Hot Water
Thermostat

Selector
Switch

Burner
Viewing
Window

0

THERMOSTAT

0

THERMOSTAT

0

SELECTOR

bar

0

4

3

2

1

Indicator
Neons

Red
Reset
Button

White
Reset
Button

RESET

RESET

Alpha 240E and Alpha 280E

Alpha 240/280

Содержание 240E

Страница 1: ...7 532 12 Service Listed 0051 Alpha 240 280 Range of Wall Mounted Fan Assisted Room Sealed Gas Fired Combination Boilers For use with Natural Gas only Leave these instructions with the User Nepicar Hou...

Страница 2: ...ty over the central heating Note The Alpha 240P and 280P use a permanent pilot for lighting the burner and the Alpha 240E and 280E burner is lit electronically 2 USER CONTROLS Pull the controls panel...

Страница 3: ...r Overheat thermostat has operated press white reset button see Fig 1 to reset not applicable to Alpha 240P and 280P Electrical supply to the boiler is on Boiler is supplying hot water Boiler is suppl...

Страница 4: ...ler automatically until the temperature of the water in the heating system has been raised To turn the boiler off for longer periods Switch off the electrical supply to the boiler and on the Alpha 240...

Страница 5: ...iler will not operate When the supply is restored the boiler will return to normal operation However in the case of the Alpha 240P and 280P check that the pilot is alight by viewing through the window...

Страница 6: ...K if fitted The clock allows you to set the times at which the boiler will operate to provide central heating It does not affect the supply of domestic hot water which is always available whatever the...

Страница 7: ...aller Or Check that the electrical supply to the boiler is on If so Check that all controls are calling for heat i e room thermostat clock If so When this button is illuminated the burner has failed t...

Страница 8: ...pared but we reserve the right to alter the specification at any time in the interest of product improvement Alpha Therm Limited 1999 11 99 D101 Part No 920 033 2 Alpha Therm Limited Nepicar House Lon...

Отзывы: