IPBELLv2
-
User manual
12
12.
CPU module
13.
Connection of cable FK1 Expansion Module (s) - Flat cable, on both sides of
the red connector on the side not matter, and also the order of the expansion
modules does not matter
14.
Switching contact screw terminal of
first relay
(NC= closed in stand by,
NO=open in stand by and COM= common output)
15.
UTP cable connection (Ethernet, LAN,net)
16.
Switching contact screw terminal of
second relay
(NC= closed in stand by,
NO=open in stand by and COM= common output)
17.
Connection 2 buttons
18.
Connection LEDs lighting name cards
19.
Two inputs (middle terminal is common for both) for door sensors or EXIT
buttons (programmable)
20. Input
for powering IPBELLV2 12V AC / DC (consumption cca 300mA max.)
We reccomend use DC power supply
21.
Output 12V DC, max. 300mA, for example to power low consumption
electrical lock via PoE powering of IPBELLV2
22.
MicroSD card slot
– Insert SD card before switch ON of door entry and do
not také out during all operation time!
1.7 Power supply - terminal (20)
12V power supply can be DC and AC, not depending on the polarity of
the 12V max. current 300mA.
The power supply can also be used to power the lock, it is recommended
12V / 1A.
You can also use a 24V DC power supply. Usage is mainly at
installations where power supply is already exists and is used for example
attendance system or sliding gates. Not to use source AC, DC only. When
connected not depends on polarity.
1.8 The exit button, door sensor - terminal (19)
Exit button is used for direct switch control. Each switch can be set to
switch on one or two pulses. Door sensor switch at the door (usually magnetic),
which guards the doors are closed.