Specifications for Alpha CXCI/CXCI+ Cordex Controller Integrated Model Continued
Alpha Technologies Ltd.
707-492-B1 Rev C
Printed in Canada. © 2011 Alpha Technologies Ltd. ALPHA and CORDEX are trademarks of Alpha Technologies Ltd. All Rights Reserved.
Page 2 of 2
Hardware Specifications, CXCI/CXCI+
CPU:
Coldfire
Display:
4 digit LCD
Front Panel Controls:
Display pushbutton toggle switch for voltage (V) or current (A)
CXCI/CXCI+ reset switch (soft reset button; hold for 3 seconds to reset IP)
LED’s:
System OK (Green)
Power System Minor Alarm (Yellow)
Power System Major Alarm / Controller Fail (Red)
Audio:
Built-in speaker for alarm and popup message tones
Dimensions:
88mm H x 26mm W x 280mm D
(3.5” H x 1” W x 11“ D)
Weight:
0.34 kg (0.75 lb.)
Mounting:
Integrated on Cordex 2RU series 19” and 23” shelves
Relay Outputs:
Four (4) Form C, 60Vdc 1A maximum
Digital Inputs:
Two (2), 0 to 60Vdc
Analog Inputs:
One (1) DC voltage, 0 to 60Vdc
One (1) DC current, ±50mV
Two (2) temperature, self-powered Alpha sensor (max 12Vdc)
CXCI Communication Ports:
Ethernet RJ-45, Alpha Modem DB-9, CAN [see shelf specifications]
CXCI+ Communication Ports: Ethernet RJ-45, CAN [see shelf specifications]
Software Specifications, CXCI/CXCI+
CXCI
Software version 2.05
CXCI+
Software version 3.1x (x indicates the latest release)
Recommended Signal Wire Sizes (as per UL/CSA)
Wire Size Range:
0.14 to 1.50mm
2
(#26 to #16 AWG)
Temperature Range:
0 to 50°C
(32 to 122°F)
CAUTION – TO REDUCE RISK OF FIRE, USE ONLY 0.14mm
2
(#26 AWG) OR LARGER WIRE.
The above information is valid at the time of publication. Consult factory for up-to-date ordering information.
Specifications are subject to change without notice.