background image

 

 

                                  

BRAVE 

– user guide

 

28 

5   Descriprion of programmable parametres  

 

Parametres  always  starts  by  fix,  mandatory  part  (  adress)  and  variable 

part 

– it is your dial. Range and explanation is always under each table . All is 

dial  like  it  is  written  in  table.  You  dont  dial  any  confirmation  character.  After 
savings  into  memory  you  get  back  confirmation  tone.  When  dialled  value  is 
incorrect you get immediatelly error tone. 

5.1  Direct numbers dial 

– memories 

Parametr  Value 

description 

Default 

tt nn… 

Number nn under button tt 

tt

 

– button number (memory), always has 2 digits  [01-99] 

nn

 

–  phone  number  up  24  digits  which  you  desire  to 

save.  For  saving  further  characters  use  assignments 
mentioned in table. 
Numbers  saved  in  parametr  1  are  numbers  of   

first 

group

, or numbers of  

DAY mode

Default settings doesnt erase as same as changed those 
saved numbers. 
 
 

Parametr  Value 

Description 

Default 

tt nn… 

číslo 

nn

 

pod tlačítkem 

tt

 

tt

  

–  button number (memory), always has 2 digits  [01-99] 

nn 

–  phone  number  up  24  digits  which  you  desire  to 

save. 

For 

saving 

further 

characters 

use 

assignments mentioned in table. 

Numbers  saved  in  parametr  1  are  numbers  of   

second 

group

, or numbers of  

NIGHT mode

Default settings doesnt erase as same as changed those 
saved numbers. 
 

 
Note:

  switching  DAY/NIGHT  mode stays  in  door  intercom even  after  line  disconnection 

and  version  (C)  this  mode  switch  up  current  time  (when  this  feature  is  activated  - 
parametr 084) 

Note:

    at  version 

Brave  Slim  -  C 

and

  Brave  Slim  -  LC

  are  available  max.  2  buttons  - 

tt=01-02 

 
 
 
 

description 

dial 

0 - 9 

0 - 9 

** 

Flash 

* # 

Pause 

* 0 

description 

Dial 

0 - 9 

0 - 9 

** 

Flash 

* # 

Pause 

* 0 

Содержание Brave Slim - C

Страница 1: ...Brave Slim C Brave Slim LC Brave Slim C C Brave Slim LC C User guide Version 1 0 Brave Door Intercom...

Страница 2: ......

Страница 3: ...solution surface installation only IP 44 casing protection LED cards lighting Integrated analog color camera C C LC C 1 2 relay with 8 different operational modes possibility to use electrical lock PS...

Страница 4: ...2 3 CAMERA C VERSION ONLY 18 2 4 ACCSSESORIES 19 2 4 1 Weather hood 19 2 4 2 TimeRelay 19 2 4 3 DistyBox 19 2 4 4 Power supply 12V 20 2 4 5 Programming cable USB 20 2 4 6 BlackBox 20 3 DOOR INTERCOM...

Страница 5: ...TING 42 5 7 TIME PROGRAMM AUTOMATIC DAY NIGHT SWITCHING C 45 5 8 DEFAULT SETTTING AND ERASING 47 5 9 PROGRAMMING TERMINATION 47 5 10 PARAMETRES OVERVIEW 48 6 TECHNICAL PARAMETRES 52 6 1 ELEKTRICAL PAR...

Страница 6: ...pulses 3 x 6 codes for each relay code by buttons at doors Adjustable number of rings before pick up an incoming call Adjustable parameters of tone dial length of Flash and Pause Adjustable parametre...

Страница 7: ...ber of rings After picking up and password inserting you can programm the unit by phone Outgoing call connection between intercom and phone has been done by dial from intercom for example by button pr...

Страница 8: ...arked Model C is version equiped by full colour analog camera Model C comfort has special features marked by C Model M modular has marked M in mechanical Slim solution is not produced And it is mentio...

Страница 9: ...5 PCB Schematics All functional and connectional elements are marked by red rounded number at bellow picture Explanation follow on next page Pict 1 Brave Slim mother board 1 3 7 11 version C only rel...

Страница 10: ...PBX which has problems with current consumption on its extensions during start Siemens 5 Camera lighting up switch ON OFF lighting of space before camera via infra LED 6 Cards lighting switch ON OFF...

Страница 11: ...It is useful mainly at installations where power supply is already installed and it is used for sliding doors RFID etc The heating has control element to restrict power The remaining components are d...

Страница 12: ...BRAVE user guide 12 2 Installation 2 1 Assembly 2 1 1 Assembly of Brave Slim front panel...

Страница 13: ...BRAVE user guide 13 2 1 2 Assembly of cards backlighting 2 1 3 Wall mounting of Brave Slim Make the mounting by attached pack with screws and plug drill 5mm...

Страница 14: ...14 2 1 4 Replacing of cards backlighting after wall mounting 2 1 5 Cards exchange name cards Every button has own card label holded by plastic flag via picture You can print out paper labels from spe...

Страница 15: ...1 5 and camera is either activated automatically when intercom is active or is permanently ON DIP 7 Camera lighting up by infra LED is either active with camera DIP 5 or you can permanently switch OF...

Страница 16: ...inversaly fire emergency exit 3 Combination of doors with electrical lock and sliding gate at fencing 4 Extending of previous example 3 about second doors with progressive opening this feature is set...

Страница 17: ...BRAVE user guide 17 Pict 2 Examples of relay connection...

Страница 18: ...parametres videonorm PAL CCIR sensor CMOS 1 3 picture area 5 78x4 19mm resolution 628x582pixel 380 rows video output 1V p p 75 ohm automatic profit control 18dB minimal lighting 3LUX automatic lens sh...

Страница 19: ...alphatechtechologies cz 2 4 3 DistyBox This optional modul is plastic box allows you to connect analog unit phone intercom into wireless system DECT GAP for example Siemens line GigaSet TopCom line B...

Страница 20: ...It must be ordered individualy 2 4 5 Programming cable USB USB cable is not part of packaging It must be ordered individualy USB drivers are downloadable on www alphatechtechnlogies cz 2 4 6 BlackBox...

Страница 21: ...OFF HOOK type 2 800 1067 1200 1333 Line hang up ON HOOK type2 1333 1200 1067 800 Command confirmation by phone 800 Alerting knocking into call Call ending alert 1333 Relay activation signal Modulovan...

Страница 22: ...y parametres 45 46 In version C you can switch DAY NIGHT mode automatically Selection of dialled number saved under the button is control by time up table parametry 00 06 2 groups numbers mode first b...

Страница 23: ...ode 2digits code is default You can shorter it by using on first digit of code during programming 351 352 361 362 Mode m 5 parametr 3125 Action Note Parametr Relay Evaluation of correct external code...

Страница 24: ...person in telephone connection with Brave intercom for example Mr Scott 3 3 1 Outgoing call Outgoing call is a call from door intercom generated by visitor After door intercom dial is ringing a phone...

Страница 25: ...and you can talk Other possibilities are the same like in case of outgoing call capture 3 3 1 First exception is first 10sec where you can dial and service password parametr 44 By this you enter prog...

Страница 26: ...capture 3 1 page 21 4 1 2 Parametres programming Stand by stage of programming is announced by programming tone into which door intercom always returns after time out 5sec whenever you started to pro...

Страница 27: ...ll the time when programm BraveSet is running The door intercom stays pasive until moment of USB cable disconnection When you loose connection please disconnect USB cable from door intercom and connec...

Страница 28: ...e Numbers saved in parametr 1 are numbers of first group or numbers of DAY mode Default settings doesnt erase as same as changed those saved numbers Parametr Value Description Default 2 tt nn slo nn p...

Страница 29: ...ntercom picks up and open by hanging up m 3 closed for time of line OFF HOOK and more for time t1 t4 after hang up lighting closed when door intercom picks up and stays closed for time t1 t4 after doo...

Страница 30: ...1 t4 of relay r Parametr Value Description Default 32 rp hh In mode DAY NIGHT password hh for relay r in order p 1 5 for 1 pulse and p for 2 pulses 00 999999 33 rp hh In mode DAY password hh for relay...

Страница 31: ...command for relay activation as same as door intercom hang up parametr 43 aa bb 1 command has always 2 digits but when you want control relay by 1 digit only from keypad of phone then you have possibi...

Страница 32: ...8 432 8 362 9 You are in communication with door intercom unit Dial command for open sliding gate 9 First pulse starts sliding the gate and second pulse stop it The size of spot for person entrance is...

Страница 33: ...relay2 in mode 1 by which you control sliding gate opening where door intercom open the gate and after car passing the gate is closed Then control by phone could make unwillingly permanent gate openi...

Страница 34: ...9 155 266 g command order 1 2 they are two to be possibility hang up door intercom when each relay is used bb command to hang up door intercom by phone 2 digits 1 It is profitable setup the same comma...

Страница 35: ...on Note Switching into DAY or NIGHT mode stays setup even after power line disconnection from door intercom Parametr Value Description Default 47 e Door intercom dial mode 0 1 1 e dial numbers mode e...

Страница 36: ...time for which door intercom is OFF HOOK This time you can prolong by dial character during a call by phone or parametr 42 Setting of time is up table Parametr Value Description Default 53 w Time betw...

Страница 37: ...p 04 99 12 h after dial termination calculate number of CRT control ring tones When number is higher than hh then hang up range 04 99 Dial is repeated in case of 2 groups mode Parametr Value Descripti...

Страница 38: ...uration time ms range 1 6 tj 100 600ms p Time of pause duration is calculated inserted number x 100 400 pause duration time ms range 1 0 tj 500 1400ms time p is also time of pause between numbers at p...

Страница 39: ...3 u Acoustic signalling knocking to call 0 1 0 In default it is switch off By activation of this feature you can identify at PBX calling from door intercom just up knocking into call Possible values a...

Страница 40: ...lt 66 i Suppression of DTMF reception from microphone 0 1 0 In default the suppression of DTMF reception from MIC is off i 0 Due this you can activate relay by personal dialler without ringing to pers...

Страница 41: ...mode after line connection and after 3sec the door intercom makes initialization It delays line picks up after line voltage connection activation status PBX restart When this feature is not efficient...

Страница 42: ...ng When you dont press any digit within 5sec then setup value is saved and you hear confirmation tone CAUTION We dont recommend factory setting if neccessary Parametr Value Description Default 74 c So...

Страница 43: ...ronment we recommend higher value with combination of parametrs 71 75 77 Parametr Value Description Default 77 s Fast switching voice automatic 1 4 4 is slowest 2 At parametres 75 76 is descriped prin...

Страница 44: ...X can compensate losses on wiring In default the feature is off k 0 You can setup in two levels depending on line current of PBX short circuit current I0 PBX current I0 k dial Feature is off 0 20mA 50...

Страница 45: ...have to setup the time By dial a 0 you deactivate automatical switching Parametr Value Description Default 081 hhnn Time settings hh hours nn minutes 082 ddmmyyw Date settings dd day mm month yy year...

Страница 46: ...nn starts day and hours kk and minutes jj starts night 00000000 07 overwrite copyright setting from sunday 00 into whole week By parametres 00 06 are setting times of automatic switching DAY NIGHT for...

Страница 47: ...ametres 5x only 5 only 86 Default settings for parametres 6x only 6 only 87 Default settings for parametres 7x only 7 only 80 Default settings for parametres 0x only 0 only Parametres 81 and 82 makes...

Страница 48: ...for closing relay r 1 pulse 00 99 0 9 155 266 36 r cc command aa from phone for closing relay r 2 pulses 00 99 0 9 150 260 37 r ss time ss sec relay closing r for time t1 t4 01 99 105 205 38 r p Rela...

Страница 49: ...ration time space between numbers 1 0 4 800ms 507 uu Transmitting level of DTMF dial in dBm 04 16 10 508 p preemphase DTMF 0 1 0 509 S Listening in DTMF level 1 4 2 61 z Acoustic signalling confirmati...

Страница 50: ...k and minutes jj starts night 00000000 01 hhnnkkjj monday time setting hours hh and minutes nn starts day and hours kk and minutes jj starts night 00000000 02 hhnnkkjj tuesday time setting hours hh an...

Страница 51: ...for parametres 3x only 3 only 84 Default setting for parametres 4x only 4 only 85 Default setting for parametres 5x only 5 only 86 Default setting for parametres 6x only 6 only 87 Default setting for...

Страница 52: ...dial level 6 and 8 dB 1 20 60 mA Sensitivity of tone dial min 40 dB 20 60 mA Sensitivity of tones detector min 30 dB 20 60 mA Powering of backlight relays and heating 12Vss 2V 10 12Vst 2V Max consumpt...

Страница 53: ...Day 1gr 107 24 Number under button 8 Day 1gr 108 24 Number under button 9 Day 1gr 109 24 Number under button 10 Day 1gr 110 24 Number under button 11 Day 1gr 111 24 Number under button 12 Day 1gr 112...

Страница 54: ...6 Password relay 1 1 pulse Day 3314 6 Password relay 1 1 pulse Day 3315 6 Password relay 1 2 pulses Day 331 6 password relay 2 1 pulse Day 3321 6 password relay 2 1 pulse Day 3322 6 password relay 2...

Страница 55: ...pulses rel 2 sec 302 2 Leaving button relay 1 0 1 2 3 1 2 Leaving button relay 2 0 1 2 3 2 2 Dial type tone pulse 0 1 41 1 Call prolongation character 42 1 Brave hanging up by phone 1 431 2 Brave han...

Страница 56: ...ression of DTMF reception from microphone 0 1 66 1 BabyCall 0 1 67 1 Number of buttons on panel Up model 6 1 Delayed start Siemens 6 1 Reception loudness TRH 01 16 71 2 Transmission loudness MIC 01 16...

Страница 57: ...BRAVE user guide 57 Tuesday hhnnkkjj 02 8 Wednesday hhnnkkjj 03 8 thursday hhnnkkjj 04 8 friday hhnnkkjj 05 8 saturday hhnnkkjj 06 8...

Страница 58: ...JR 2011 verze 1 0 V 11 Producer Distributor Sales date...

Отзывы: