Local Web Server Access:
•
You may also test the connection using a computer and a standard Ethernet cable. Connect the computer
to the Ethernet port on the transponder, launch an Internet browser (e.g. Internet Explorer) and enter
192.168.100.1 in the address field. The General Configuration page shown below will appear and display
connectivity, power levels and power supply status information such as alarms, output voltage, output current
and individual battery voltages. System Name, System Location, System Contact and Common Logical ID
may be edited on this page; when prompted for a User Name and Password, use “Alpha” and “AlphaGet”.
•
Remote Web Server Access:
•
Connect the computer to the cable modem network, launch an Internet browser (e.g. Internet Explorer) and
enter the designated transponder IP address in the address field. The General Configuration page will appear
(Fig. 8).
Fig. 8, General Page
If the home page of the DM3.0 Series Transponder does not load using IP address 192.168.100.1, the Local
Area Connection on the computer may require a Temporary Static IP address to be manually configured to
192.168.100.2
NOTICE
:
Worldwide Co
r
porate Offices
Alpha
and Outback Energy
GmbH
reserves the right to make changes to the products and information contained in this document without notice.
Copyright © 20
20
Alpha
and Outback Energy GmbH
. All
Rights reserved.
Headquarter Germany
Hansastrasse 8
D-91126 Schwabach
Tel: +49 9122 79889 0
Fax: +49 9122 79889 21
France and Benelux
Spain
For
more
information please visit
Russia
Africa
Eastern Europe
Middle East