18
Error Information
Detects the temperature of the current fixture(LED, drive, housing) and displays it on
the Smart Touch LCD screen. 45˚C or less is cyan, 46~69˚C is yellow, and 70˚C or more is red.
If the temperature exceeds 75˚C, the actual LED output will decrease.
If it exceeds 85˚C, the actual LED output will be 0%, and 'Temperature Error Please Check Device !!' will be displayed.
The error messages are only displayed on the main screen and the fixture ID screen.
Even if the temperature falls to the normal range, It does not disappear.
In this case, normalize the temperature of the equipment and restart it.
Temperature
Sensor
When the DMX512 network connection is lost, the DMX512 address number in main screen
and the fixture ID number blink. Check the connection and reconnect.
Network
Connection