21
Product name.
ALPHA 2000
Error Information
Temperature Sensor
Network Connection
45
˚
C
or less is cyan
46~69
˚
C
is yellow
70
˚
C
or more is red
If the
temperature
exceeds
75
˚
C
the actual LED
output will
decrease.
If it exceeds
85
˚
C
the actual LED
output will be 0%
If it exceeds 85˚C, the actual LED output will be 0%, and
“Temperature Error!!”
“Please Check Device!!”
will be displayed.
The error messages are only displayed on the main screen and the fixture ID screen.
Even if the temperature falls to the normal range, It does not disappear.
In this case, normalize the temperature of the equipment and restart it.
Detects the temperature of the current fixture(LED source, housing) and displays
it on the Smart Touch LCD screen.
When the DMX512 network connection is lost, the DMX512 address number on main
screen and the fixture ID screen blinks. Reconnect after checking the connection status.