27
Product name.
ALPHA 1500
No
Control Property
Value
(Example)
Description
User Setting
Remarks
1
Identify On
N/A
Device identification action
active
Enable
Identify device = Same as On
2
Identify Off
N/A
Device identification action
inactive
Enable
Identify device = Same as Off
3
Cold Reset
N/A
Device reset(restart)
Enable
Same as Warm reset
4
Warm Reset
N/A
Device reset(restart)
Enable
Same as Cold reset
[ Lamp Controls ]
RDM Protocols (2/3)
No
Device Property
Value
(Example)
Description
User
Setting
Remarks
1
Device Model Description
ALPHA 1500
Model number
of the device
Disable
2
Manufacturer Label
ALPHA LITE
Name of the
manufacturer
Disable
3
Device Label
SPOT123
Fixture name and
management number
Enable
ex) Input : SPOT123
· Name : SPOT123
· Management # : 123
- Automatic recognition of
up to 4 digits. If there is
no number, the default
is '001'.
4
Software Version Label
M0E-v1.10-
v5.27-180928
Software version
Disable
5
DMX Personality
1 Ch. Mode
DMX channel mode
and color temperature
setting
Enable
See (Table 1)
6
DMX Start Address
1
DMX address
Enable
1~512 Range
7
Device Hours
N/A
N/A
Display only, no actual response.
8
Lamp Hours
N/A
N/A
Display only, no actual response.
9
Lamp State
N/A
N/A
Display only, no actual response.
10
Lamp On Mode
N/A
N/A
Display only, no actual response.
11
Display Invert
On
LCD screen display
direction
Enable
· Off : 0˚
· On : 180˚
· Auto : Current opposite
direction
12
Identify Device
Off
Selected fixture blinking
indication
Enable
· Off : Deactivates blinking
· On : Activates blinking
13
Speed Set
15
Dimming delay Setting
Enable
0~40 range
The larger the value, the slower
the dimming.
14
Display Mode
0
Normal screen / Fixture
ID screen transitions
Enable
· 0 : Normal screen
· 1 : Fixture ID screen
15
Max. Temp
75
Fixture maximum
temperature display
Enable
Use for initialization if necessary
Содержание ALPHA 1500
Страница 6: ...5 Product name ALPHA 1500 Dimensions ...