DMX Protocols (2/3) Channel 2 : White Color Temperature 

DMX 

Value 

Function 

0~1 

2500 

2~3 

2550 

4~5 

2600 

2650 

7~8 

2700 

9~10 

2750 

11 

2800 

12~13 

2850 

14~15 

2900 

16 

2950 

17~18 

3000 

19~20 

3050 

21~22 

3100 

23 

3150 

24~25 

3200 

26~27 

3250 

28 

3300 

29~30 

3350 

31~32 

3400 

33 

3450 

34~35 

3500 

36~37 

3550 

38~39 

3600 

DMX 

Value 

Function 

40 

3650 

41~42 

3700 

43~44 

3750 

45 

3800 

46~47 

3850 

48~49 

3900 

50 

3950 

51~52 

4000 

53~54 

4050 

55~56 

4100 

57 

4150 

58~59 

4200 

60~61 

4250 

62 

4300 

63~64 

4350 

65~66 

4400 

67 

4450 

68~69 

4500 

70~71 

4550 

72~73 

4600 

74 

4650 

75~76 

4700 

77~78 

4750 

DMX 

Value 

Function 

79 

4800 

80~81 

4850 

82~83 

4900 

84 

4950 

85~86 

5000 

87~88 

5050 

89~90 

5100 

91 

5150 

92~93 

5200 

94~95 

5250 

96 

5300 

97~98 

5350 

99~100 

5400 

101 

5450 

102~103 

5500 

104~105 

5550 

106~107 

5600 

108 

5650 

109~110 

5700 

111~112 

5750 

113 

5800 

114~115 

5850 

116~117 

5900 

DMX 

Value 

Function 

118 

5950 

119~120 

6000 

121~122 

6050 

123~124 

6100 

125 

6150 

126~127 

6200 

128~129 

6250 

130 

6300 

131~132 

6350 

133~134 

6400 

135 

6450 

136~137 

6500 

138~139 

6550 

140~141 

6600 

142 

6650 

143~144 

6700 

145~146 

6750 

147 

6800 

148~149 

6850 

150~151 

6900 

152 

6950 

153~154 

7000 

155~156 

7050 

DMX 

Value 

Function 

157~158 

7100 

159 

7150 

160~161 

7200 

162~163 

7250 

164 

7300 

165~166 

7350 

167~168 

7400 

169 

7450 

170~171 

7500 

172~173 

7550 

174~175 

7600 

176 

7650 

177~178 

7700 

179~180 

7750 

181 

7800 

182~183 

7850 

184~185 

7900 

186 

7950 

187~188 

8000 

189~190 

8050 

191~192 

8100 

193 

8150 

194~195 

8200 

- 24 - 

DMX 

Value 

Function 

196~197 

8250 

198 

8300 

199~200 

8350 

201~202 

8400 

203 

8450 

240~205 

8500 

206~207 

8550 

208~209 

8600 

210 

8650 

211~212 

8700 

213~214 

8750 

215 

8800 

216~217 

8850 

218~219 

8900 

220 

8950 

221~222 

9000 

223~224 

9050 

225~226 

9100 

227 

9150 

228~229 

9200 

230~231 

9250 

232 

9300 

233~234 

9350 

DMX 

Value 

Function 

235~236 

9400 

237 

9450 

238~239 

9500 

240~241 

9550 

242~243 

9600 

244 

9650 

245~246 

9700 

247~248 

9750 

249 

9800 

250~251 

9850 

252~253 

9900 

254 

9950 

255 

10000 

Содержание A8-PLUS-J

Страница 1: ...BASE SOFT LIGHT A8 PLUS J USER MANUAL December 2019 ...

Страница 2: ... as safety helmet during work 3 Be sure to fix the safety chain on the product when installing and moving 4 Please install the signs below for people to bypass when install the product on high truss 5 The work should be done under the direction of approved specialist who is trained in safety and mechanical installations WARNING 2 ...

Страница 3: ...Menu Tree 14 Setting Product Information 15 DMX Mode Channel Change 16 DMX Mode Address Setup 16 User Mode Setup 17 User Mode Intensity CCT Tint Adjust 17 Color Mode Setup 18 Color Mode RGB Saturation Intensity Adjust 18 Sleep Mode Function 19 Master Function 19 RDM On Off Setup 19 Dimming Speed Setup 19 Fixture ID Setup 20 RDM Fixture Label Setup 20 Error Information Temperature Sensor 21 Network...

Страница 4: ...d not exposed to elements A Plus Series is possible to express 2 500 10 000K color temperature and full color by combining LED which can control color temperature and RGB LED so it is used to create various sets of atmosphere A Plus Series that uses high efficiency CRI LED light sources can increase lifetime and reduce maintenance cost and power consumption 4 ...

Страница 5: ...Fixture Exterior View Stirrup Smart Touch LCD Screen Handle Fixed Knob 5 Barn Door Connector Panel Clamp ...

Страница 6: ...mm inch Dimensions A8 Plus 6 ...

Страница 7: ...pply Range AC 100 240V 50 60Hz Power Consumption 400W White Light CCT Full 2 500 10 000K VCT Colored Light Full RGB W 4 Color gamut with Hue and Saturation control CRI 95 98 Dimming 0 100 16 bit Control 5 PIN DMX In and Out Smart Touch LCD Controller RDM Option Wireless DMX512 Wireless RDM Remote Device Management Supported Ambient Temperature Operation 20 45 C IP Rating IP20 Estimated LED Lifetim...

Страница 8: ...Door Assembly Fit the bottom of the barn door into the groove on the top of the body Slide the barn door along the groove Fit the bolt on the upper barn door to the groove Turn the bolt clockwise to fix it 8 ...

Страница 9: ...ser Lens Change Pull back the latches across the diffuser lens Pull out the diffuser lens to the left 9 When replacing the diffuser lens insert it with the smooth side facing inward Rough side facing forward ...

Страница 10: ...3 If the operating voltage is out of the proper voltage range SMPS function may be degraded or damaged Power Connection AC power at 100 240V 50 60Hz 10 1 USB PORT for ADMINISTRATOR ONLY 2 POWER OUT 3 POWER IN 4 DMX OUT 5 DMX IN 6 POWER ON OFF SWITCH Do not connect USB without administrator s permission 1 2 3 4 5 6 ...

Страница 11: ...e for connect the DMX controller to other XLR output 1 Shield 2 Signal 3 Signal 4 Not Connected 5 Not Connected Connect the DMX output of the first lighitng fixture in DMX chain to the DMX input of the next fixture and connect one output to the input of the next fixture until all fixtures are connected In the last lighting fixture the DMX cable must be end with a terminator 120 Ω resistor in DMX o...

Страница 12: ... Locked Fixture ID Screen Locked When the fixture is turned on the Smart Touch screen automatically locked To unlock the touch screen touch the finger icon three times If you do not touch for 30 seconds the lock is reset A A A ...

Страница 13: ... 8 Home Return to the main screen 9 DMX512 Mode Address Setup Set channel mode and DMX512 address 10 User Mode Setup Set Intensity CCT and Tint manually 11 Color Mode Setup Set RGB lighting color Saturation and Intensity 12 Setting Setting or changing the function of the equipment 13 Fixture ID Displays numbers for equipment management 14 Equipment Information Displays the help that describes the ...

Страница 14: ...ation Description of fixture ID Θ Information Basic equipment information Θ Rotate Θ Home Main Screen Θ DMX512 Mode DMX mode select DMX address input Θ Information DMX channel value Θ User Mode Intensity setup Color temperature setup Tint value setup Θ Information Description of each function Θ Color Mode RGBW color setup Saturation setup Intensity setup Θ Information RGBW value Menu Tree 14 ...

Страница 15: ...tail information which manufacturer model name firmware version UID number current fixture temperature power hours LED hours website and product manual download link by selecting INFORMATION button in main screen Product Information 15 ...

Страница 16: ... used to adjust by DMX512 signal 1 1 Ch mode Dimming 3 3 Ch mode Dimming CCT Tint 5 5 Ch mode Dimming CCT Tint Cross Fader Color Macro 8 8 Ch mode Dimming CCT Tint Cross Fader Red Green Blue White Pressing the Info button in DMX512 MODE displays each channel information and value To return to the previous screen press the Info button again Support channels and features vary by product DMX Mode Cha...

Страница 17: ...User Mode It is used when the user directly manipulates the equipment Intensity The number indicates the current brightness value of the fixture and is displayed from 0 to 100 CCT The number indicates the current color temperature value of the fixture and is displayed from 2 500 to 10 000K Tint The number indicates the current tint gamma value of the fixture and is displayed from 1 00 Magenta to 1...

Страница 18: ...or drag the color user want Hue Drag and select the Hue user want Saturation The number indicates the current saturation value of the fixture and is displayed from 0 to 100 White The number indicates the current White LED brightness value of the fixture and is displayed from 0 to 100 Pressing the Info button in COLOR MODE displays description of each function To return to the previous screen press...

Страница 19: ...hat allows user to synchronize and control all fixtures without a console connection The default is off which means the fixture follows the instructions of the console Dimming speed setup The number indicates the current dimming speed value of the fixture and is displayed from 0 to 40 The higher the value the slower the dimming speed and 15 is default speed Pressing the Info button in SETTING disp...

Страница 20: ...sh and the management number in the Device Label field The entered contents are displayed in the upper left corner The fixture ID is automatically displayed in 3 or 4 digits from automatically recognized 4 digits in contents If user do not enter any number the fixture ID is displayed as 001 Pressing the Info button in FIXTURE ID displays description of the function It is the number value 001 to 99...

Страница 21: ...and Temperature Error Please Check Device will be displayed The error messages are only displayed on the main screen and the fixture ID screen Even if the temperature falls to the normal range It does not disappear In this case normalize the temperature of the equipment and restart it Temperature Sensor When the DMX512 network connection is lost the DMX512 address number in main screen and the fix...

Страница 22: ...el 3 is 255 only Red channel 4 Green channel 5 Blue channel 6 and White channel 7 color values are displayed As the DMX value of channel 3 Cross Fader increases RGB and White values become darker The DMX value of channel 3 adjusts relatively the brightness ratio of channel 2 and channel 4 7 Color Macro Channel 4 is Color Macro express rainbow gradation effect The order is Red Green Blue 22 ...

Страница 23: ...0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Color Macro 8 1 0 255 0 100 Dimmer 2 0 255 0 100 Color Temperature CCT 3 0 119 120 255 See DMX Protocols 3 Tint 4 0 255 0 100 Cross Fader 5 0 255 0 100 Red 6 0 255 0 100 Green 7 0 255 0 100 Blue 8 0 255 0 100 White 23 DMX Protocols 1 3 ...

Страница 24: ...nction 118 5950 119 120 6000 121 122 6050 123 124 6100 125 6150 126 127 6200 128 129 6250 130 6300 131 132 6350 133 134 6400 135 6450 136 137 6500 138 139 6550 140 141 6600 142 6650 143 144 6700 145 146 6750 147 6800 148 149 6850 150 151 6900 152 6950 153 154 7000 155 156 7050 DMX Value Function 157 158 7100 159 7150 160 161 7200 162 163 7250 164 7300 165 166 7350 167 168 7400 169 7450 170 171 750...

Страница 25: ... Value Output Value Function 3 0 10 0 No Effect 11 20 1 00 Full Magenta 21 119 0 99 0 01 99 1 Magenta 120 145 0 No Effect 146 244 0 01 0 99 1 99 Green 245 255 1 00 Full Green DMX Protocols 3 3 Channel 3 Tint 25 ...

Страница 26: ...S YES SENSOR_DEFINITION YES SENSOR_VALUE YES DMX_PERSONALITY YES YES DMX_PERSONALITY_DESCRIPTION YES STATUS_MESSAGES YES Lamp Controls No Control Property Value Example Description User Settings Remarks 1 Identify On N A Device identification action active Enable Identify device Same as On 2 Identify Off N A Device identification action inactive Enable Identify device Same as Off 3 Cold Reset N A ...

Страница 27: ...X Start Address 1 DMX address Enable 1 512 Range 7 Device Hours N A N A Display only no actual response 8 Lamp Hours N A N A Display only no actual response 9 Lamp State N A N A Display only no actual response 10 Lamp On Mode N A N A Display only no actual response 11 Display Invert On LCD screen display direction Enable Off 0 On 180 Auto Current opposite direction 12 Identify Device Off Selected ...

Страница 28: ...cription 8 Ch Model Device RGB 1 Ch Mode 1 Ch Mode 3 Ch Mode 3 Ch Mode 5 Ch Mode 5 Ch Mode 8 Ch Mode 8 Ch Mode 1 Ch 2500K 1 Ch Mode 2500K Color Temperature 1 Ch 2900K 1 Ch Mode 2900K Color Temperature 1 Ch 3000K 1 Ch Mode 3000K Color Temperature 1 Ch 3500K 1 Ch Mode 3500K Color Temperature 1 Ch 4000K 1 Ch Mode 4000K Color Temperature 1 Ch 4500K 1 Ch Mode 4500K Color Temperature 1 Ch 5000K 1 Ch Mod...

Страница 29: ... information and questions please visit our website or call ALPHA LITE Co Ltd 2nd Floor 5 8 Gyeongin ro 88 gil Yeongdeungpo gu Seoul Republic of Korea 07363 Email Tel Fax Web hello alpha lite net 82 2 6317 0464 82 2 2039 0464 www alpha lite net ...

Отзывы: