6.5 Installing the control panel
NOTE
The control can be inserted in a recess in the
front panel of the unit or can be installed on
the wall.
Insert the control in the unit and connect
1.
If required: Remove masking plate from the slot.
To do this, dismantle the front panel (
“Dismantle
housing panels for transport with handcart or
carrying the unit”, page 10), press the lugs
together and push out of the openings.
2.
Remove film from the plastic element of the front
panel.
3. Position the control in the recess in the front unit
panel.
4. Cut the cable to length generously so that the
front panel can be removed and placed to the side
of the unit. Do not cut the cable ties for strain relief
of the LIN bus cable at the electric control box.
● LIN bus cable approx. 1.1 m from the fixing of
the strain relief at the electrical control box
●
All other cables approx. 1.2 m
5. Use cable ties (
separate pack) to fix the LIN bus
cable to a web of the masking plate around 20 cm
in front of the connector (strain relief).
200 mm
6. Push the cable through the opening in the front
panel of the unit from below and into the control.
7. Press the lugs of the control into the openings in
the front panel of the unit.
Mount the control on the wall and connect
IMPORTANT
Mount the wall bracket with control panel
only ver-
tically
on a wall!
1.
Release the rear bracket from the control.
2.
If visually unattractive: Cut off the lugs on the rear
of the control (are only needed to insert in the
front panel).
3.
Mark 2 drillholes (
Dimensional drawing “Wall-
mounted bracket”, page 35).
4.
If cables are fed in from underneath: Break out
the web at the bottom in the middle of the wall
bracket. Use side-cutters if necessary.
5.
Fix the wall-mounted bracket
(②)
with 2 wall
plugs
(①)
and 2 screws
(③)
.