Hook the tension springs included with delivery
into the holes provided for them on the air intake
side of heat pump 4…
Hook the tension springs into the assembly tail that
has been screwed on to the air duct…
Secure a protective cap over the assembly rail…
Repeat – the process on the air output side.
NOTICE.
Don't forget:
After the air ducts have been secured to the
heat pump, close the opening between the wall
duct and the air duct using the betonite water-
stop tape included with delivery.
NOTICE.
Secure the air ducts to the cover using appropri-
ate measures.
SCREEN FRAME ASSEMBLY
Screw the screen frame to the wall ducts on both the air
intake and output sides.
NOTICE.
The screen frame serves no technical purpose; it
is present solely to create a seamless transition
to the wall duct.
WIRE MESH GRILLE AND WEATHER/RAIN GUARDS
ASSEMBLY
Remove the wire mesh grille and the weather / rain
guards as well as the assembly frame and fastening
material from their respective boxes…
From the outside of the house inwards, insert the
assembly frame into the wall duct on the air intake
side and secure with screws…
8 x