14
Subject to change without notice | 83054400dUK – Translation into English of the original German operating manual | ait-deutschland GmbH
Push the screws M12 x 40 (2x) supplied through the
fan and the top metal tab and secure with nuts M12…
Lower the unit at the installation location. Make
sure that the frame of the unit is in full contact with
the underlying surface and the unit is positioned
horizontally…
Undo the mounting nuts at the top metal tab and
remove the corresponding screws.
Then pull the fan out of the unit and screw tightly
back onto the unit frame (do not forget the spring
washers)…
Remove guide rods and attach all facing panels back
onto the unit.
INSTALLATION
Set the unit on a stable, solid and level, preferably sound-
insulated surface. Make sure that the foundation is de-
signed for the weight of the heat pump.
ATTENTION
In the air outlet area the air temperature is ca.
5 K below the ambient temperature. Under cer-
tain climatic conditions, therefore, an ice layer
can form in the air outlet area.
Install the heat pump so that the air blower does
not blow in the direction of footpaths.
ATTENTION
Do not tilt the unit more than a maximum of 45°
(in any direction).
NOTICE.
Always observe the installation plan for the re-
spective model. Note the size and minimum
clearances.
Installation plan for respective model.
Set up the unit so that the switch cabinet side (= operat-
ing side) is accessible at all times.
MOUNTING THE AIR DUCTS
NOTICE.
Note the air blow-out direction of the unit.
–
Units with the abbreviation L in the model desig-
nation blow the air out to the left (when viewed
from the control side).
ATTENTION
Use only original accessories or air ducts rec-
ommended by the manufacturer (fibreglass light-
weight concrete ducts).
Mount air ducts only according to the installa-
tion plan for the respective unit.
Installation plan for respective model.
WALL DUCT(S) ASSEMBLY
Remove the parts necessary for the assembly of the
wall duct(s) from their respective boxes...
Next, interlock the 2 pieces of the wall duct(s) that
belong together, as illustrated in the following draw-
ing. Use the lubricant supplied upon delivery to help
in this process...