Operation
42
900-0161-01-01 Rev B
Table 4 AUX Mode Functions
Name Purpose
Triggers
Settable Points
Start Stop
Load
Shed
Operates designated
loads normally; turns off
loads in severe conditions
High Vdc
Low Vdc
High temp
Low output Vac
High input Aac
Low & high Vdc
On & Off delay
Gen
Alert
Starts generator to
charge batteries
Low Vdc
High Vdc
Low & high Vdc
On & Off delay
Fault
Signals that the Radian
shut down due to error
Error present
Error cleared
None
Vent
Fan
Runs fan to vent batteries
while charging
High Vdc
Below high Vdc
High Vdc
Off delay
Cool
Fan
Runs fan to cool Radian
Internal sensor
> 60°C
Internal sensor < 49°C None
DC
Divert
Turns on DC dump load
to prevent overcharging
High Vdc
Low Vdc
Low & high Vdc
On & Off delay
GT
Limits
Signals disconnect of
grid-tied Radian due to
AC conditions
GIP parameters
not met
GIP parameters met
None
Source
Status
Signals that the Radian
accepted an AC source
AC source accepted
AC source
disconnected
None
AC
Divert
Turns on AC dump load
to prevent overcharging
High Vdc
AC source accepted
Low Vdc
High output load
High temperature
Low & high Vdc
On & Off delay
Содержание OutBack Power GS8048A
Страница 1: ...Radian Series Inverter Charger GS4048A GS8048A Operator s Manual ...
Страница 6: ...Table of Contents 6 900 0161 01 01 Rev B THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 20: ...Operation 20 900 0161 01 01 Rev B NOTES ...
Страница 56: ...Troubleshooting 56 900 0161 01 01 Rev B NOTES ...
Страница 67: ...Specifications 900 0161 01 01 Rev B 67 NOTES ...