background image

900-0135-01-00 Rev A.vsd\Overview\2012-03-21

©2012 OutBack Power Technologies.  All Rights Reserved.

Page 1

Overview

In    23.2 V     0.0 A
Out   27.6 V     0.0 A

0.000 kW    0.0 kWH

AUX:   OFF     Sleeping

In    23.2 V     0.0 A
Out   27.6 V     0.0 A

0.000 kW    0.0 kWH

AUX:   OFF     Sleeping

 

Î

Charger  Aux   Light 

  EQ    Misc  Advanced 
  Logging    Stats 

EXIT   

Í

   

Î

  GO

LCD Screen

Main Menu

Soft Key 

Buttons

Soft Key 

Commands

<EXIT>, 

<GO> etc.

Navigation:

1

2

Advances to the 
end-of-day screens

Advances to the 
main menu screens

IN   23.2 V     0.0 A
OUT  27.6 V     0.0 A

0.000 kW   0.0 kWH

AUX: OFF       Sleeping

Status Screen

OutBack              24V

Power

Systems

Charge Controller

Startup Screen

NOTE:  

See page 2-4 of this guide for menu maps for setting the 

versions, changing the language of the screens, and accessing 
the main menu.

See the 

FLEXmax Series Owner’s Manual 

for details on the 

settings available in the main menu.  

PV Input Voltage

Battery Voltage

AUX Status

Instantaneous Kilowatts

PV Input Current
Output Current

Mode of Operation

Daily Accumulated 
Kilowatt-hours

Select this option to proceed

Available menus

Adjusts the set points value

Switches between devices on the 
ports of the Communications HUB

Soft Key Color Code:

Navigation colors

Selects a function (e.g., ON, OFF, AUTO)

NOTE:  Soft key functions will vary depending on the selected 
menu and are defined by the word above the key in the LCD.

If accompanied by a dashed 
line, pressing that soft key will 
return the user to the location 
identified by the dashed line.  
This will vary depending on the 
devices in the system.

Indicates a 1-screen movement within a 
Menu.  These are color coded according to 
their function or purpose.

Models:

FLEXmax 80

:  80 amps maximum continuous 

output current (up to 40°C without thermal derating)

FLEXmax 60

:  60 amps maximum continuous 

output current (up to 40°C without thermal derating)

Features:

Supports 12, 24, 36, 48, and 60 Vdc 
battery voltages

Backlit display screen (LCD) with 80 characters 
(4 lines, 20 characters per line)

Last 128 days of operational data logging

Voltage step-down capability allowing a higher PV 
array voltage configuration

Manual and automatic equalization cycles

Screen Versions:

English
Spanish
Australian

(English with different default settings)

FLEXmax 80 Charge 

Controller

FLEXmax 60 Charge 

Controller

Recommended Input PV Wattage 

per Charge Controller*

Battery Bank 

Voltage

Maximum PV 

Input Wattage 

for the 

FLEXmax 80

Maximum PV 

Input Wattage 

for the 

FLEXmax 60

12 Vdc

1000 W

750 W

24 Vdc

2000 W

1500 W

36 Vdc

3000 W

2250 W

48 Vdc

4000 W

3000 W

60 Vdc

5000 W

3750 W

LCD Screen

Soft Keys

PV 

+

PV 

BAT

BAT 

+

MATE 

Port 

(RJ45)

RTS 

Port 

(RJ11)

Terminals

Torque = 

4 Nm (35 in-lb)

1

2

The interior design is identical in each model.

*Standard Test Conditions

Содержание OutBack Power FLEXmax 80

Страница 1: ... FLEXmax 80 FLEXmax 60 Overview ...

Страница 2: ...ck Power Technologies All Rights Reserved WARNING SHOCK HAZARD This information is for use by qualified personnel who meet all local and governmental code requirements for licensing and training for the installation of electrical power systems with DC voltage up to 150 Vdc Consult the FLEXmax Series Owner s Manual for detailed information on safety and installation procedures ...

Страница 3: ...ary depending on the selected menu and are defined by the word above the key in the LCD If accompanied by a dashed line pressing that soft key will return the user to the location identified by the dashed line This will vary depending on the devices in the system Indicates a 1 screen movement within a Menu These are color coded according to their function or purpose Models FLEXmax 80 80 amps maxim...

Страница 4: ...s and amp hours Main Menu Screen To access the Main Menu Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO IN 23 2 V 0 0 A OUT 27 6 V 0 0 A 0 000 kW 0 0 kWH AUX OFF Sleeping 2 1 Press the soft key until 141 is displayed on the LCD 2 Press the ENTER or ENTRA soft key to accept the password and move forward to the Select Version Screen PASSWORD CONTRASENA 141 Entra ENTER PASSWORD CONTRASENA 1...

Страница 5: ...n Relay EXIT TIME VOLT Hold Delay 01 0 Time 00 Seconds BACK DLY Absorb Float EQ Relative Volts 0 0 00 2 BACK HYST AUX MODE Diversion Relay Output Off OFF EXIT NEXT SET MODE Returns to the Vent Fan Screen 1 Vent Fan PV Trigger AUX MODE Vent Fan Output Off OFF EXIT NEXT SET MODE AUX MODE PV Trigger Output Off OFF EXIT NEXT SET MODE AUX MODE ERROR OUTPUT Output Off OFF EXIT NEXT SET MODE AUX MODE Nig...

Страница 6: ...D Previous day 128d 0000Ah 00 0 KWH 011Vp 00 0Ap 0 00kWp MAX 29 4V ABS 01 00 MIN 29 2V FLT 00 00 EOD 128 days past Range 2 9 minutes Continued from the previous page Main Menu Screens continued Charger Aux Light EQ Misc Advanced Logging Stats EXIT GO BATTERY EQUALIZE Volts 30 0 EXIT NEXT EQV EQV BATTERY EQUALIZE Time 01 Hours EXIT NEXT EQV EQV BATTERY EQUALIZE 1 Hours 30 0 Volts Check water level ...

Страница 7: ...LITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION b ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE WHETHER DIRECT INDIRECT CONSEQUENTIAL OR INCIDENTAL WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER S RISK Warranty Summary OutBack Power Technologies warrants that the products it man...

Страница 8: ...North America 5917 195th Street N E Arlington WA USA 1 360 435 6030 900 0135 01 00 Rev A ...

Отзывы: