AlphaESS cannot guarantee M48112-P absolute safety

Fire

 

In case of fires, make sure that the following equipment is available near the system.

 SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on  

    Personal Protective Equipment 89/686/EEC. 

 Novec 1230, FM-200, or dioxide extinguisher.

Note:
ABC extinguishers are not effective when the battery pack is on fire.

Batteries may explode when heated above 150°C. If possible, move the battery pack to a safe area 
before it catches fire.

Leaking Batteries

If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed to 
the leaked substance, immediately perform the actions described below.

 

Inhalation

: Evacuate the contaminated area, and seek medical attention.

 

Contact with eyes

: Rinse eyes with flowering water for 5 minutes, and seek medical attention.

 

Contact with skin

: Wash the affected area thoroughly with soap and water, and seek medical 

    attention.

★ 

Ingestion

: Induce vomiting, and seek medical attention.

5.  Emergency Situations

LED Display

Error Code

LED Ring

Description

Description

Hardware Error

Hardware Error

Hardware Error

Circuit Breaker Open

DIP Difference

LMU Disconnect(Slave)

SN Missing

LMU Disconnect(Master)

Wait for automated recovery.
In case problem is not resolved, 
call in for repair.

Reconnect the communication cable

Reconnect the communication cable.

Error 01

Error 03

Error 05

Error 06

Error 07

Error 08

Error 09

Error 10

Red light 
flickering 
every 3 
seconds.

Close circuit breaker after Shutting down 

the battery system.

Enter the serial number, restart the system 

or call in for repair.

Keep consistence of DIP switches,

restart the system.

Wet Batteries

If the battery pack is wet or submerged in water, do not let people access it, and then contact 
AlphaESS or an authorized dealer for technical support.

Damaged Battery

Damaged batteries are dangerous and must be handled with the utmost care.
They are not fit for use and may pose a danger to people or property.
If the battery pack seems to be damaged, pack it in its original container, and then return it to 
AlphaESS or an authorized dealer.

Note: Damaged batteries may leak electrolyte or produce flammable gas. If such a damage 
occurs, immediately contact AlphaESS.

Содержание M48112-P

Страница 1: ...Battery Module M48112 P EN V 1 0 User Manual ...

Страница 2: ...copy right of Alpha ESS Co Ltd with all rights reserved Please keep the manual properly and operate in strict accordance with all safety and operating instructions in this manual Please do not operate the system without reading through the manual ...

Страница 3: ...2 Introduction 2 1 Features 2 1 Specifications 3 Switch On Off 3 1 Switch On Off 3 2 LED Display 4 Error and Alarm Code 5 Emergency Situations 6 Warranty 6 1 Warranty 6 2 Limitation of Liability 01 01 01 01 01 01 03 02 03 04 04 04 ...

Страница 4: ...lphaESS Do not install the battery in any environment of temperature below 10 Cor over 50 C and humidity over 80 Do not touch the system with wet hands Do not put any heavy objects on the top of the battery The M48112 P battery pack has the following features Photovoltaic system This battery pack is designed for household photovoltaic systems Battery management system BMS The battery packs built i...

Страница 5: ...m shall be turned on in the correct sequence to avoid any damage Note When the battery is working pressing the power button for 5 seconds LCD display will light up for 30 seconds SOC LED Ring Description SOC 5 5 SOC 25 25 SOC 50 50 SOC 75 75 SOC 95 SOC 95 Standby Green light flickering 1 s Work Green light flickering 10s LED Display Protection Code LED Ring Description Temperature difference High ...

Страница 6: ...the contaminated area and seek medical attention Contact with eyes Rinse eyes with flowering water for 5 minutes and seek medical attention Contact with skin Wash the affected area thoroughly with soap and water and seek medical attention Ingestion Induce vomiting and seek medical attention 5 Emergency Situations LED Display Error Code LED Ring Description Description Hardware Error Hardware Error...

Страница 7: ...shipping or insurance company as soon as the container packaging is unloaded and such damage is identified Failure to follow any all of the user manual the installation guide and the maintenance regulations Improper use or misuse of the device Insufficient ventilation of the device The maintenance procedures relating to the product have not been followed to an acceptable standard Force majeure vio...

Страница 8: ...tralia Pty Ltd 1300 968 933 Australia Only australia alpha ess com www alpha ess com au Suite 2 Level 1 530 Botany Road Alexandria NSW 2015 Alpha ESS Co Ltd 86 0 513 806 068 91 info alpha ess com www alpha ess com JiuHua Road 888 Nantong High Tech Industrial Development Zone Nantong City 226300 Alpha ESS Co Ltd Official Website WeChat ...

Отзывы: