Error Code
- 03 -
AlphaESS cannot guarantee M48112-P absolute safety
Fire
In case of fires, make sure that the following equipment is available near the system.
★
SCBA (self-contained breathing apparatus) and protective gear in compliance with the Directive on
Personal Protective Equipment 89/686/EEC.
★
Novec 1230, FM-200, or dioxide extinguisher.
Note:
ABC extinguishers are not effective when the battery pack is on fire.
Batteries may explode when heated above 150°C. If possible, move the battery pack to a safe area
before it catches fire.
Leaking Batteries
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or gas. If one is exposed to
the leaked substance, immediately perform the actions described below.
★
Inhalation
: Evacuate the contaminated area, and seek medical attention.
★
Contact with eyes
: Rinse eyes with flowering water for 5 minutes, and seek medical attention.
★
Contact with skin
: Wash the affected area thoroughly with soap and water, and seek medical
attention.
★
Ingestion
: Induce vomiting, and seek medical attention.
5. Emergency Situations
LED Display
Error Code
LED Ring
Description
Description
Hardware Error
Hardware Error
Hardware Error
Circuit Breaker Open
DIP Difference
LMU Disconnect(Slave)
SN Missing
LMU Disconnect(Master)
Wait for automated recovery.
In case problem is not resolved,
call in for repair.
Reconnect the communication cable
Reconnect the communication cable.
Error 01
Error 03
Error 05
Error 06
Error 07
Error 08
Error 09
Error 10
Red light
flickering
every 3
seconds.
Close circuit breaker after Shutting down
the battery system.
Enter the serial number, restart the system
or call in for repair.
Keep consistence of DIP switches,
restart the system.
Wet Batteries
If the battery pack is wet or submerged in water, do not let people access it, and then contact
AlphaESS or an authorized dealer for technical support.
Damaged Battery
Damaged batteries are dangerous and must be handled with the utmost care.
They are not fit for use and may pose a danger to people or property.
If the battery pack seems to be damaged, pack it in its original container, and then return it to
AlphaESS or an authorized dealer.
Note: Damaged batteries may leak electrolyte or produce flammable gas. If such a damage
occurs, immediately contact AlphaESS.