3 Installation
The FMC-PLUS-QSFP-DD is designed to plug into the FMC+ front panel connector on a compatible carrier. The
retaining screws should be tightened to secure the FMC+.
The FMC-PLUS-QSFP-DD it should be removed in a certain way for the FMC+ connector not to be damaged.
Here is a video from Samtec showing the removal procedure of this kind of connectors: see https://
vimeo.com/158484280
Note:
This operation should not be performed while the host carrier is powered.
3.1 Handling instructions
Observe precautions for preventing damage to components by electrostatic discharge. Personnel handling the
board should take SSD precautions and avoid flexing the board.
3.2 IO Voltage Selection
The required IO voltage range (VADJ) for the FMC+ is 1.2V to 3.3V. This is stored in a ROM on the FMC+, as
per VITA 57.4 for automatic configuration of supplies. The carrier is responsible for detecting and setting the IO
voltage accordingly.
Page 4
Installation
ad-ug-1404_v1_0.pdf