background image

Copyright© 2002-2006, Alpha Communications®, All Rights Reserved.

AWD075

Rev. 5 (07/06)

VH30AK Video

Monitor Station (shown)

APPLICATION

The VH30AK series video-intercom system allows any
number of VH30AK series inside handset sta-
tions to communicate with one or more door entry stations
with (or without) a built-in B&W camera. When used as
an apartment video-intercom system, the VH30AK can
view the caller, speak with the caller, and activate an
electric door release (if required).

PROCEDURE

1. Read installation instructions for each unit to deter-

mine equipment location and installation method.

2. Install housings and wiring.
3. Install equipment.
4. Check wiring and connect. Observe all local

and national electrical codes.

5. Apply power and check system operation.

VH30AK Series (B&W Apartment Type)

Video-Intercom Installation and Use

Instructions, used with the VCU6

System Power Supply Unit(s)

HOUSING INSTALLATION AND

EQUIPMENT LOCATION

INSIDE HANDSET STATION(s)

Locate stations where needed at convenient speaking and
viewing height, about 4.5 feet (137 cm) from the finished
floor. Unit can be secured directly to the finished wall
surface or can be mounted over a single gang electrical
'gem' box or single gang electrical plaster ring.

DOOR ENTRY STATION(s)

Locate door entry station(s) at a convenient speaking
location at the building entry location(s).

NOTE: For best

picture (video) quality DO NOT POINT CAMERA
INTODIRECTSUNLIGHT!!!

SYSTEM TRANSFORMER(s)

The SS146 (and T1240) system transformers may be
plugged into an accessible source of 117 VAC, preferably
within 50' (15 meters) of the VCU6 system power supply
unit(s), but no closer than 3 feet (1 meter).

ELECTRIC DOOR OPENER (OPTIONAL)

The DO-001 (or equivalent 12-16VAC type) electric door
release is installed in the door jamb in place of the regular
door strike plate. It can be electrically operated by the
VH30AK video handset station(s).

WIRING

INSIDE HANDSET STATIONS

Run 2 conductor #18AWG (common), 4 conductor
#22AWG (common), RG59/U (common) and 1 conduc-
tor #22AWG (selective) cable from video handset
to video handset to the central equipment location
(where the VCU6 unit is found). Additional cables may be
used to serve other monitors on other risers (lines). Cables
may be straight or twisted pair type and may be solid or
stranded conductors. Depending upon additional system
options and/or functions you may need to run additional
wires. Please consult the factory for more information.
RG59/U coax cable must be good quality, ALL COPPER,
with minimum 95% copper braiding. As with all systems,
we recommend running some spare wires, for future use.

Route cable away from AC power wiring, transformers,
fluorescent lights, light dimmers or other electrical de-
vices. Protect cable from damage. Shielded cable should

Содержание VH30AK

Страница 1: ...t a convenient speaking location at the building entry location s NOTE For best picture video quality DO NOT POINT CAMERA INTODIRECTSUNLIGHT SYSTEM TRANSFORMER s The SS146 and T1240 system transformer...

Страница 2: ...ton is making contact by shorting out the two 2 wires on the back of the button 3 NO PICTURE AT MONITOR If screen is NOT LIGHTING UP check for approximately 16VDC at and terminals on monitor PC board...

Страница 3: ...leasechecktiming after re adjusting If that doesn t correct the problem check this out On the VCU6 amplifier power supply there are three 3 sets of and terminals for the Monitors marked M1 M1 M2 M2 M3...

Страница 4: ...pigtailwirescomingfromterminals O and LL ontheVH250P P C Board TheBlack O wiremustjumptoterminal O onthemonitorhandsetandtheRed LL wire must jump to terminal S on the monitor handset or the monitor wi...

Страница 5: ...see the special camera installation and connection instructions found on page 8 and do not power as shown above 3 DO NOT CONNECT MORE THAN 10 MONITORS PER RISER LINE 4 Observe all local and national e...

Страница 6: ...tions found on page 8 and do not power as shown above 3 DO NOT CONNECT MORE THAN 10 MONITORS PER RISER LINE 4 Observe all local and national electrical and building codes 5 All terminals connections s...

Страница 7: ...nal electrical and building codes 5 All terminals connections shown may not be in the order that they appear on the equipment TYPICAL WIRING DIAGRAM FOR DUAL ENTRANCE SYSTEM WITH S T R STYLE CAMERA AN...

Страница 8: ...IS SUPPLIED TO THE CAMERA USE A METER TO CHECK THE POLAR ITY OF THE NEWLY SPLICED CABLE BEFORE CONNECTING IT TO THE CAMERA THE CENTER PIN MUST BE POSITIVE USE ONLY THE SUPPLIED POWER SUPPLY POWER SUPP...

Отзывы: