Alpha Communications TekTone Tek-View VM104 Скачать руководство пользователя страница 5

IL498 Tek-VIEW

®

 • Page 5

Copyright © TekTone Sound & Signal Mfg., Inc. All Rights Reserved.

Video Monitor (VM104):

A. Connect all necessary wires as shown in the connecting

diagram (Figure 5). Refer to Figure 6 for dual entrance
wiring. IH357 and IH358 housings include four knock-
out holes for cable inlet.

B. Mount the VM104 to the IH357 and IH358 ring housing

using the adapter plate.

Transformer (SS250):

A. Connect transformer 16 volt terminals to PK314A, termi-

nals T1 and T2. Connect transformer primary to 117
VAC observing all applicable electrical codes.

SYSTEM CHECK-OUT

Check entire system according to the operating instructions,
turning each monitor on individually so that if a problem
exists it may be easily identified. If the system does not
operate as indicated, refer to 

Troubleshooting 

section.

OPERATING INSTRUCTIONS

Entrance Panel (VM320B, VM600B):

1. Momentarily press button corresponding to desired suite.
2. Reply in a normal voice when spoken to. Reply is hands-

free.

3. When door release buzzes, enter through door.

Suite Station (VM104):

1. When call tone is heard, pick up intercom handset.
2. Adjust picture brightness and contrast as necessary using

the slide control switches located just below the lower
right corner of the video screen.

3. Identify caller on the video screen and converse with

them.

4. The door may be opened by pressing the door release

button marked 

DOOR

.

A monitor will stay on for approximately 1 minute when
called. Picture is delayed by approximately 3 to 5 seconds.
When the door release is activated, or when a second caller
rings another suite, the monitor will shut off.

Calls may also be initiated from the VM104 by pressing the
video monitor button marked 

MONITOR

. This activates the

camera and may be used to re-initiate a call that has been
canceled, or to monitor the entrance panel. The monitor will
stay on for approximately 1 minute. Only 1 monitor at a
time should be on using video monitor button.

If standby control is switched 

ON

, the red LED will light and

the monitor will remain on standby, ready to operate when
another call is placed from the entrance panel. NOTE:
Performance may vary with large or small installations. If
no video contact with the entrance is desired, or if a tenant is
leaving the suite, the standby switch may be turned 

OFF

.

Audio communication will still operate normally.

SYSTEM MAINTENANCE

Entrance Panel (VM320B):

Directory panels are accessible by removing the self-tapping
metal screw(s) located in the top L-channel just above each
panel. After removing screws, lift L-channel away from
frame. Panel can then be removed. Apply directory listings
as desired, and replace panels by reversing the above
procedure.

Control Unit (PK314A):

Each PK314A has a 5 amp, 3AG fuse for overload protection.
Replace this fuse only with the same type and rating. If this
fuse continually opens, check for incorrect wiring or
equipment failure.

TROUBLESHOOTING

System:

Check for 15–18 VDC on PK314A terminals P and N. This
voltage should also appear between the + and - terminals of
all video monitors. NOTE: The PK314A has an electronic
current limiter that will shut the unit off in the presence of a
short circuit on the output terminals. When the short is
removed, the output should appear again. The current limiter
will also act in case of an overload (too many monitors),
which will cause the output to switch on and off rapidly.
This may be noticed only if all monitors are turned on.

If power supply function is satisfactory and monitors turn
on (screen lights up) but no picture is displayed, check the
camera by connecting a monitor directly. If the camera does
not turn on, check for 12 VDC on camera terminals CP and
CN, then check for 10 VDC on PK314A terminal CT
(terminal N is negative). Terminal CT voltage comes from
the video distribution system (PK320).

Problems with the video distribution system are usually due
to incorrect wiring. Check that CT terminal on each video
monitor connects directly to the distribution amplifier
(PK320) that is feeding the video signal to it. This is
necessary because the PK320 is turned on by the connection
from the CT terminal on the active monitor to PK320
terminal A. Terminal B on the PK320 connects to PK314A
terminal CT to turn on the camera.

Intercom:

Incorrect wiring is the cause of most intercom problems.
Check the PK314A by disconnecting the common wires,
connecting a monitor directly, and then checking
communication. The telephone operation is independent of
the video section and should operate even if the video does
not. The use of twisted pair wiring as shown on the
connecting diagram (Figure 5) is essential for operation.

Video Monitors:

Video monitors are best checked by substitution. If the red
standby LED is not illuminated when the unit is turned on,
verify that +17 VDC is present. If present, replace the
monitor; if not, troubleshoot wiring for +17 VDC.

Содержание TekTone Tek-View VM104

Страница 1: ...TekTone dealer for details PROCEDURE 1 Read installation instructions before proceeding 2 Install housings and wiring 3 Connect wires and install equipment 4 Apply power and check operation VM600B En...

Страница 2: ...ning width A 5 Use TekTone s AM series combination button directory panels for the smallest applications Figure 2 OH Series Entrance Panel Housing Figure 3 IH357 Ring IH358 Box and VM104 Mounting Plat...

Страница 3: ...the control unit must be installed away from the entrance panel observe notes regarding wiring and locate where the operating temperature of 0 C 40 C will not be exceeded Transformer The transformer m...

Страница 4: ...ont panels into the frame following the directions included with the directory panel distancesgreaterthan500 use20gaugewire Maximum distancefromamplifierforcommunicationwiresis1000 D Wire gauge size f...

Страница 5: ...TEM MAINTENANCE Entrance Panel VM320B Directory panels are accessible by removing the self tapping metal screw s located in the top L channel just above each panel After removing screws lift L channel...

Страница 6: ...C Post Office Key Switch Normally Open N P Shield 4 3 2 1 RG59U CT 3 Cond 18 2 Twisted Pairs 22 Shielded if not in metal conduit to Entrance Panel Push Button Selective Wire X RG59 U CONNECTOR BOARD X...

Страница 7: ...14A 1 Pair Shielded 22 1 Pair 22 1 22 RG59U 1 Pair 22 V2 PK417 Y2 PK417 1 Pair 18 D1 PK417 T2 PK314A D2 PK417 T2 PK314A Camera Video Output Entrance 2 Camera Video Output Entrance 1 Camera CN Terminal...

Страница 8: ...PK417 Y1 2nd PK417 CN PK314A D1 2nd PK417 T2 PK314A X X CP CN G2 2nd PK417 M2 2nd PK417 S2 2nd PK417 V2 2nd PK417 Y2 2nd PK417 CN PK314A D2 2nd PK417 T2 PK314A X X CP CN Door Release 3 Camera CP Micro...

Страница 9: ...Panel Push Button Selective Wire X RG59 U Connector X V V G G 1 2 3 4 X CT 1 2 3 4 X CT VM104 VM104 to additional VM104 units 20 units maximum per riser 200 feet maximum cable length per riser PK320...

Страница 10: ...380MA 12VDC PK314A 1 2 3 4 M G Z W S C E L N P T1 T2 CL CT CP CN 16VAC SS250 117 VAC Post Office Key Switch Normally Open N P 4 3 2 1 RG59U CT 3 cond 18 2 twisted pairs 22 shielded if not in metal co...

Страница 11: ...IL498 Tek VIEW Page 11 Copyright TekTone Sound Signal Mfg Inc All Rights Reserved Figure 10 Rear View of VM104 Black White Video Monitor Overall Dimensions H 8 25 209 mm W 7 38 187 mm D 2 25 57 mm...

Отзывы: