Tek-COM

® 

PK724 Series

Installation Instructions

IL537

Section B

Rev. 12  - 09/2004

APPLICATION

The Tek-COM

®

 Intercom provides fast, natural-voice, room-

to-room communications. The 

MONITOR

 

function permits

listening to any room but may be released to obtain full
privacy. Door answering is made simple by an automatic,
hands-free reply circuit. A number of optional accessories
are available to provide a complete home signaling and
communications system.

PROCEDURE

1. Read the installation instructions for each unit to deter-

mine equipment locations and installation methods.

2. Install the housings and wiring.

3. Install the equipment.

4. Check all wiring and connections.

5. Apply power and check system operations.

HOUSING INSTALLATION AND

EQUIPMENT LOCATION

Inside Stations

Locate stations where needed at a convenient speaking
height—about 4.5' (1.4 m) from the finished floor. Do
not install stations back-to-back or on a common wall
between rooms. Install IH102 rings for IR704B/BD
stations as shown in Figure 1a. Reverse the ring for
mounting on finished walls. Install IH110R housings with
IR804A stations as shown in Figure 1b.

Outside Stations

Locate door stations at a convenient speaking height on
exterior walls near an entrance. The front of the housing
must be flush with the finished wall to ensure weather
protection. Install IH101 housings with OR101, OR501B,
and OR502 stations (Figure 1c). Use standard single-
gang rings (Figure 1d) for mounting OR601, OR603,
and OR604AW stations. Install OR501S or OR502S for
surface mount with no housings required.

Amplifier

The amplifier is designed to be surface mounted and must
be located away from any source of direct heat or cold
and in an accessible location. Keep it at least 3' (1 m)
away from transformers, light dimmers, and other
electrical devices or wiring.

Transformer

The SS105B plug-in type transformer must be provided
with an electrical outlet at a convenient location, and
should be located within 50' (15 m) of the amplifier. If
the SS102A pigtail type transformer is used, it may be
installed on the fuse panel or other accessible source of
117VAC, preferably within 50' (15 m) of the amplifier.

Accessories

Optional accessories are to be installed where needed.

The 

DO-001A 

electric door release is installed in the door

jamb in place of the regular door strike plate.

7.82"

5.35"

Figure 1b

IH110R

Figure 1d

Single Gang Box

4.1"

5.45"

5.95"

4.7"

Figure 1a

IH102

3.85"

5.55"

Figure 1c

IH101

Figure 1 — Station Housings

ALPHA COMMUNICATIONS

®  

 •   42 Central Drive   •   Farmingdale, NY 11735-1202

Toll-Free Technical Line: 1-800-666-4800   •   Phone: (631) 777-5500  •   Fax: (631) 777-5599

Website: www.alpha-comm.com   •   Email: [email protected]