Tek-COM
®
PK724 Series
Installation Instructions
IL537
Section B
Rev. 12 - 09/2004
APPLICATION
The Tek-COM
®
Intercom provides fast, natural-voice, room-
to-room communications. The
MONITOR
function permits
listening to any room but may be released to obtain full
privacy. Door answering is made simple by an automatic,
hands-free reply circuit. A number of optional accessories
are available to provide a complete home signaling and
communications system.
PROCEDURE
1. Read the installation instructions for each unit to deter-
mine equipment locations and installation methods.
2. Install the housings and wiring.
3. Install the equipment.
4. Check all wiring and connections.
5. Apply power and check system operations.
HOUSING INSTALLATION AND
EQUIPMENT LOCATION
Inside Stations
Locate stations where needed at a convenient speaking
height—about 4.5' (1.4 m) from the finished floor. Do
not install stations back-to-back or on a common wall
between rooms. Install IH102 rings for IR704B/BD
stations as shown in Figure 1a. Reverse the ring for
mounting on finished walls. Install IH110R housings with
IR804A stations as shown in Figure 1b.
Outside Stations
Locate door stations at a convenient speaking height on
exterior walls near an entrance. The front of the housing
must be flush with the finished wall to ensure weather
protection. Install IH101 housings with OR101, OR501B,
and OR502 stations (Figure 1c). Use standard single-
gang rings (Figure 1d) for mounting OR601, OR603,
and OR604AW stations. Install OR501S or OR502S for
surface mount with no housings required.
Amplifier
The amplifier is designed to be surface mounted and must
be located away from any source of direct heat or cold
and in an accessible location. Keep it at least 3' (1 m)
away from transformers, light dimmers, and other
electrical devices or wiring.
Transformer
The SS105B plug-in type transformer must be provided
with an electrical outlet at a convenient location, and
should be located within 50' (15 m) of the amplifier. If
the SS102A pigtail type transformer is used, it may be
installed on the fuse panel or other accessible source of
117VAC, preferably within 50' (15 m) of the amplifier.
Accessories
Optional accessories are to be installed where needed.
The
DO-001A
electric door release is installed in the door
jamb in place of the regular door strike plate.
7.82"
5.35"
Figure 1b
IH110R
Figure 1d
Single Gang Box
4.1"
5.45"
5.95"
4.7"
Figure 1a
IH102
3.85"
5.55"
Figure 1c
IH101
Figure 1 — Station Housings
ALPHA COMMUNICATIONS
®
• 42 Central Drive • Farmingdale, NY 11735-1202
Toll-Free Technical Line: 1-800-666-4800 • Phone: (631) 777-5500 • Fax: (631) 777-5599
Website: www.alpha-comm.com • Email: [email protected]