7. ELECTRICAL SUPPLY
The boiler requires a 230/240 V ~ 50 Hz supply, fused at 3 A if a 13 A 3-pin plug is used or a 5 A fuse if any other type of plug is used.
To connect a plug:-
The colour of the wires in the mains lead of the boiler may not correspond with the coloured markings identifying the terminals
in your plug. In this case proceed as follows:-
The wire coloured green and yellow must be connected to the terminal in the plug that is marked with the letter E, or by the
earth symbol
, or coloured green or green and yellow.
The blue wire must be connected to the terminal which is marked with either the letter N or coloured black.
The brown wire must be connected to the terminal which is marked with the letter L or coloured red.
THE APPLIANCE MUST BE EARTHED.
6
GAS SAFETY REGULATIONS
Current Gas Safety (Installation and Use) Regulations:-
It is the law that all gas appliances are installed and serviced by a competent person, ie CORGI registered personnel. Failure to
install or service appliances correctly could lead to prosecution. It is in your interest and that of safety to ensure compliance
with the law. The manufacturer's instructions must not be taken in any way as over-riding statutory obligations.
The Benchmark Log Book must be fully completed by the installer on installation of the boiler. All CORGI registered installers
carry a CORGI ID card and have a registration number. Both should be recorded in your central heating Log Book. You can
check your installer is CORGI registered by calling CORGI on 01256 372300.
Manual compiled and designed by Publications 2000 - Tel: (01670) 356211
These instructions have been carefully prepared but we
reserve the right to alter the specification at any time in
the interest of product improvement.
© Alpha Therm Limited 2001.
10/01/D122
Part No. 1.015429
Alpha Therm Limited.
Goldsel Road, Swanley, Kent BR8 8EX
Tel: (01322) 669443
Fax: (01322) 615017
7
FAULT FINDING FOR THE USER
If you experience a problem of no heating, try to solve the problem by following the simple checks below before calling out a
service engineer.
Содержание SY24
Страница 25: ...25 Alpha SY24 Wiring Diagrams 9 1 ILLUSTRATED WIRING DIAGRAM 9 WIRING DIAGRAMS ...
Страница 26: ...26 9 2 FUNCTIONAL FLOW WIRING DIAGRAM Alpha SY24 Wiring Diagrams ...
Страница 28: ...28 10 3 FAULT FINDING SOLUTION SECTIONS A to F Alpha SY24 Fault Finding ...
Страница 29: ...29 Alpha SY24 Fault Finding 10 4 FAULT FINDING SOLUTION SECTIONS G to J ...