ALORAIR Zeus 900 Скачать руководство пользователя страница 5

1. Ensure the power switch is off, then unwrap the power cord and plug it into a standard 115V 

GFCI-protected outlet.

2. Point the air outlet towards the area that needs to be dried.

3. Press the Up or Down button to adjust the airflow speed on the panel.

4. Once the surface is dry, turn the unit off and unplug the power cord.

5. Wrap the power cord around the machine in a clockwise direction and secure with a clip.

6. Use the handle to move the machine to the next drying area or to storage. The units may

be stacked for transportion or storage.

NOTE:

 Always keep the units dry.

AIR MOVER

Operating Instructions

Circuit Breaker Reset

The Zeus 900 is equipped with a Circuit Breaker Reset Switch to protect from fire or shock 

risk. The Circuit Breaker switch will:

• automatically cut off power to the machine if the circuit is overloaded

• automatically cut off power to the machine if it finds a ground fault

If reset switch is flipped, complete the following steps:

1. Check the power line for any damage and ensure it is properly connected to a grounded 

outlet

2. Press the Circuit Breaker Reset Switch to restart the unit

Maintenance

Cleaning the Housing & Impeller

If dust or dirt has accumulated on the impeller, you will need to disassemble the housing  (see 

instructions on next page) to clean it. Do not use liquids to clean the impeller- only a cloth or 

pressurized air.  The housing can be cleaned with a damp, cloth but always ensure it is dry 

prior to reassembling.

NOTE:

 

Prior to use, verify that the power cord and plug are not broken.