background image

Capacity @ 80°F/60%RH:

  100 Pints Per Day

Capacity @ 73°F/60%RH:

  78

 

PPD

Airflow : 

 250 CFM

Operating Temp. Range:

  3

3.8

-105°F

Operating Relative Humidity Range:

  36%-90%

COP:

  2.7 L/kWh

Refrigerant: 

 R410A

Amperage Usage:

  6.82 Amps

Power Supply: 

 115V/60Hz/Single Phase

Outlet Requirement: 

 15 Amp, 3 

prong, GFCI

Sound Level: 

 60 dBa

Dimensions LxWxH:

  13.8” x 15.8” x 23.7”

ETL Listed: 

 Yes

Specifications

How It Works

Installation Requirements 

·

The area where the dehumidifier is located should be sealed with a vapor barrier. 

• If the unit is installed in a crawl space, all vents should be sealed.

• For proper ventilation, neither the inlet or discharge should be positioned against a wall. 
The inlet needs a minimum of 12” clearance and the discharge requires a minimum of 36” 
clearance.  

• For the best air diffusion, install the unit so that a side panel faces the wall.

• Alorair dehumidifiers are only intended for operation when the unit is upright and level 
with the feet on the ground. 

AlorAir dehumidifiers use an integrated humidistat to monitor theconditioned space. When 

the relative humidity goes above the selected setpoint, the dehumidifier will energize. Air is 

then drawn across an evaporator coil, which is cooler than the dew point of air. This means 

moisture will condense out of the air. The air is then reheated through the condenser coil and 

distributed back into the room.

3

Installation

1. Place dehumidifier on a level surface.

2. Set up the drain line

    • Remove the compression nut and slide it over the end of the hose to be attached to unit. 

    • Slide the side of hose with compression nut over the insert on the compression fitting 
completely.  

    • Tighten compression nut. 

3. Plug dehumidifier into grounded 15 amp circuit. 

• Do not place unit directly on vapor barrier. For example, use blocks or pavers to create a 
level surface. 

• If unit has been turned or flipped so that the compressor did not remain upright, place the 
unit on a level surface and wait a minimum of 2 hours before proceeding.

Key Functions

1

.

Power

Key

·

Use this button to turn the dehumidifier on and off.

·

Press once to turn machine on. You will hear two beeps and   the        light will 

illuminate green (solid or flashing depending on mode).

·

Press the power button a second time and you will hear one beep as the machine shuts 

down. Note that there is a 1 minute fan delay.   

2

.

Arrow

Buttons

·

Use

the

up

and

down

arrow

buttons

to

set

the

desired

humidity

setpoint

on

the

display

screen

.

·

The setpoint can be any number between 36%-90%. When the  indoor humidity is higher 

than the setpoint, the unit will operate.
 • Keep in mind that the displayed humidity levels are approximate   ( +/-5%)

3

.

Continuous

Mode

·

To set the unit to run continuously regardless of humidity,   simply use the down 

arrow key to set the humidity below 36%.

4

Содержание Sentinel HDi100

Страница 1: ...AlorAir Solutions INC Add 4240 Latham Street Suite D Riverside CA 92501 Tel 888 990 7469 E mail sales alorair com Sentinel HDi100 C Specifications subject to change without notice...

Страница 2: ...___ For additional questions concerning your dehumidifier contact your local installer or call AlorAir at 888 990 7469 Important Notes Always connect your dehumidifier using a grounded electrical conn...

Страница 3: ...air is then reheated through the condenser coil and distributed back into the room 3 Installation 1 Place dehumidifier on a level surface 2 Set up the drain line Remove the compression nut and slide i...

Страница 4: ...sor has been initiated but is currently warming up Once the light switches to green it means the compressor is currently in working status 5 Remote Control Instructions AlorAir Dehumidifiers can be co...

Страница 5: ...minute after the unit has shut off The AlorAir Sentinel HDi100 has an integrated condensate pump During normal operation the HDi100 will automatically drain as required If you would like to store or m...

Страница 6: ...servoir with water 16 32 ounces and flush cycle the pump at least 2x Removing the Pump 1 Remove the 9 screws on the side panel and set panel aside 2 Remove the screw holding the pump in place 3 Undo t...

Страница 7: ...or may be faulty Verify that the pump is properly installed and functioning If so unplug the unit for two minutes then restart Increase the room temperature so it is within operation range above 33 8...

Страница 8: ...cord serial and date of installation You will need this information to receive the RA number 2 If warranty service is necessary customers must contact AlorAir Tech Support by sales alorair com or loca...

Страница 9: ...ANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED IN LAW OR IN FACT INCLUDING IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE AlorAir s...

Отзывы: